background image

 
 

 

 

If the module surface becomes dirty, it may 
reduce output power.  

 

It is recommended to clean the surface of 
the module with water and a soft cloth or 
sponge, twice or more per year.  

 
 
 
 

 

A  mild  non-abrasive  detergent  may  be 
applied for persistent dirt.   

 

It  is  also  recommended  to  inspect  the 
electrical  and  mechanical  connections 
annually. 

 

If  you  need  electrical  or  mechanical 
inspection 

or 

maintenance, 

it 

is 

recommended to have a licensed authorized 
professional  carry  out  the  inspection  or 
maintenance to avoid the hazards of electric 
shock or injury. 

 

Disclaimer of Liability 

 

Panasonic  does  not  assume  responsibility 
and  expressly  disclaims  liability  for  loss, 
damage,  or  expense  arising  out  of,  or  in 
any  way  connected  with  installation, 
operation,  use,  or  maintenance  by  using 
this manual.   

 

Panasonic assumes no responsibility for any 
infringement  of  patents  or  other  rights  of 
third parties, which may result from use of 
modules.  

 

No  license  is  granted  by  implication  or 
under  any  patent  or  patent  rights.  The 
information in this manual is believed to be 
reliable,  but  does  not  constitute  an 
expressed and/or implied warranty.  

 

The  return  of  any  modules  will  not  be 
accepted  by  Panasonic  unless  prior  written 
authorization has been given by Panasonic. 

 

As part of Panasonic’s policy of continuous 
improvement,  Panasonic  reserves  the  right 

to change product specifications at any time 
without prior notice.  

 

Customer Services 

 

For  further  information,  please  visit 
http://panasonic.net/energy/solar/ 

or 

contact 

your 

Panasonic 

Authorized 

Representative. 

Figure 4.2  Junction Box  

Cable 

Negative ( - )  Positive ( + ) 

Figure 4.1 Connectors 

Option:  
Safety lock clip 

Connector 

MC

 TM 

Plug 

Cable 

Negative ( - ) 

Positive ( + ) 

Summary of Contents for HIT Power 240S Series

Page 1: ...is part of the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT Model No HIT Power 240S VBHN240SA11 and 11B HIT Power 235S VBHN235SA11 and 11B HIT Power 230S VBHN230SA1...

Page 2: ...sed Content New Edition 2013 4 19 2nd Edition 2015 3 18 1 System Fire Class Rating 2 Trademark 3 Front cover Grounding 1 Addition of System Fire Class Rating 2 Explanation of trademark 3 According to...

Page 3: ...ss diodes Do not touch a module unnecessarily The glass surface and frames get hot There is a risk of burn CAUTIONS Use a module for its intended purpose only Do not treat the back sheet frame or fron...

Page 4: ...ons see figure 1 and below Provider UniRac Inc Part number SolarMount Clamps type Top Mounting Clamps Clamp size Mid clamp and End clamp C size Unirac Part No 302003 302101 Width 1 5 38 mm Thickness 0...

Page 5: ...ock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is correct Cable conduits should be used in locations where the wiring is inaccessi...

Page 6: ...olts star washers spilt ring lock washers flat washers and the like is used to attach a listed grounding bonding device the attachment must be made in conformance with the grounding device manufacture...

Page 7: ...his will terminate the wire For more information please refer to Instruction sheet issued by Tyco Electronics Using a Grounding Clip with bolt and nut Use Tyco Electronics 1954381 2 as grounding clip...

Page 8: ...ation use or maintenance by using this manual Panasonic assumes no responsibility for any infringement of patents or other rights of third parties which may result from use of modules No license is gr...

Page 9: ...frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer...

Page 10: ...eter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw S...

Page 11: ...und holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel...

Page 12: ...System Voltage Voc 600 600 600 Factory Installed Bypass Diodes 3 3 3 Maximum series fuse A 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds 35...