background image

1

InstructIon Manual

Compact Laser Displacement Sensor

Hl-G1

 Series

Thank you for purchasing products from Panasonic Electric Works SUNX 

Co., Ltd. Please read this Instruction Manual carefully and thoroughly for 

the correct and optimum use of this product. Kindly keep this manual in a 

convenient place for quick reference.

WARNING

 

This product is intended to detect objects. Do not use it to carry out 

safety control functions to prevent accidents.

 

Never use this product as a sensing device for personnel protection.

 

In case of using sensing devices for personnel protection, use prod-

ucts which meet laws and standards, such as OSHA, ANSI or IEC 

etc., for personnel protection applicable in each region or country.

 

Install a fail-safe device in case the product is being used for pur-

poses that can lead to physical injury or serious damage.

 

● This product cannot be used in an environment containing inflam

-

mable or explosive gases.

Before use

Check the sensor head model and package contents before use.

 

sensor head model

 

Check the model number on the top of 

sensor head.

 

Package contents

 

Check that all of the following items 

are included in the package.

 -1 sensor head

 -1 Instruction Manual

 -1 set of laser warning labels

1

overview

This product is a compact laser displacement sensor, incorporating a digital 

display and controller functions.

 

The standard type has three digital outputs and 1 analog output for 

current or voltage.

 

The multifunction type additionally incorporates serial communication 

functions and can be easily controlled by host devices.

 

One out of four measurement distances can be selected for each type 
that support both NPN and PNP outputs.

2

cautions for Handling laser light

In order to prevent accidents caused by laser products and to protect the 

users, IEC, JIS and FDA established the following standards: These stan-

dards classify laser products according to their level of hazard and provide 

safety measures for the respective classes.

 

IEC: IEC 60825-1-2007 (EN 60825-1-2007)

 

JIS: JIS C 6802-2005

 

FDA: PART 1040 (PERFORMANCE STANDARDS FOR LIGHT-EMIT-

TING PRODUCTS)

laser hazard class

Classification according to IEC 60825-1-2007 (JIS C 6802-2005)

class

Model

Description of hazardous evaluation

Class 2

HL-G1

qq

-A-C5

HL-G1

qq

-S-J

Visible beam, low power. Blink response of 

eye affords protection.

Warning label and label position

Installation and operation

 

Install the product so that the laser beam is above or below eye level.

 

Do not look into the beam directly during operation. A safe distance 

from the laser (Nominal Ocular Hazard Distance: NOHD) is approx. 

0.4m.

 

The laser beam must be terminated at the end of its path by a diffuse 

reflector or an absorber.

 

Please contact Panasonic Electric Works SUNX Co., Ltd. if the system 

breaks down. It is not equipped with a function that stops laser radia-

tion automatically when the sensor head is being disassembled.

 

● Do not use the system in any other manner than specified in this 

instruction manual.

3

Wiring instructions

WARNING

Turn OFF the power supply before connecting or disconnecting the con-

nectors or performing wiring.

connections

 

When connecting or disconnecting the connectors, hold the connector 

area so that no extra force is applied to the cable.

 

Do not touch the terminals or to let foreign objects get into the connec-

tors after disconnecting them.

 

Do not apply force around the connector of the sensor head cable 

or the extension cable. Do not bend the cables near the connectors 

because the cables will be disconnected.

 

When moving the sensor head during operation, install the cables in 

such a way that they do not bend while the sensor head is moving. 

Use the multifunction type if bending the cables is inevitable as there 

are replaceable extension cables available for this type.

Wiring

 

Do not roll up the sensor cable (bundle in parallel) with other wiring. 

Keep it at least 100mm away from other wires. 

Cables should be separated from high voltage and power circuit lines. 

If this is not possible, shield the cable by running it through conductive 

material such as grounded electrical conduit.

 

Install the product as far away as possible from noise sources such as 

high-voltage lines, high-voltage devices, power lines, power device, 

machines which generate a large high-voltage ON/OFF surge, welding 

machines and inverter motors.

 

Do not pull the cable with a force more than 29.4N when wiring the 

cable when the sensor head is fixed. The cable may be bent with a 

radius of 30mm or more. However, do not bend the cable within 20mm 

of the sensor head.

20mm min.

R 30mm min.

Reviews: