Summary of Contents for HM500 Series

Page 1: ...TOUCH TERMINALS HM500 Instruction Manual ACGM0194V2EN Version 2 0 2021 04 https industry panasonic eu ...

Page 2: ...510 HM513 11 8 Installation 12 8 1 Installation environment 12 8 2 Applying the gasket 12 8 3 Installation procedure 13 9 Connections 14 9 1 HM504 14 9 2 HM507 HM510 and HM513 14 9 3 Serial port 15 9 4 Ethernet port 15 9 5 Optional plug ins 16 9 6 Power supply grounding and shielding 17 10 Battery 18 11 Cleaning faceplates 18 12 Getting started 18 13 System settings tool 19 13 1 Introduction 19 13...

Page 3: ...rammable displays of the HM500 series The following models are available HM504 Programmable display with TFT color 4 3 display touchscreen HM507 Programmable display with TFT color 7 widescreen display touchscreen HM510 Programmable display with TFT color 10 4 display touchscreen HM513 Programmable display with TFT color 13 3 widescreen display touchscreen ...

Page 4: ...sily create and manage your applications in multiple languages to meet global requirements Far East languages are supported Tools available in HMWIN Studio support easy third party translations and help reducing development and maintenance costs of the application Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art HMI features data acquisit...

Page 5: ...EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 The installation of these devices into the residential commercial and light industrial environments is allowed only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 The products are in compliance with the Restrictions on Certain Hazardous Substances RoHS Directive 2011 65 EC In...

Page 6: ...e attached to the rear cover You will have to know the type of unit you are using for correct usage of the information contained in the guide The following information is provided by the plate Product model name Product part number Month year of production Serial number Version ID of the product ...

Page 7: ...Hz 1g EN 60068 2 6 Shock 50g 11ms 3 pulses per axis EN 60068 2 27 Degree of protection IP66 front panel see note EN 60529 The front face of the unit installed in a solid panel has been tested using conditions equivalent to the stan dards shown in the Environmental conditions Even though the level of resistance unit is equivalent to these standards oils that should have no effect on the can possibl...

Page 8: ...out direct exposure to sunlight or UV rays 10 years if the surrounding air temperature is 25 C UV resistance Indoor applications After 300 hours cycled humidity in QUV accelerated weathering some yellowing and brittleness may be present see note 2 Touch screen reliability 1 milion operations 1 Extended use in environments where the surrounding air temperature is 40 C or higher may degrade backligh...

Page 9: ...s Voltage 10 32V DC see note Current rating at 24V DC 0 4A 0 65A Weight 1kg 1kg Model HM510 HM513 Display Backlight TFT Color LED Colors 64K Resolution 800x600 1280x800 Display size inch 10 4 widescreen 13 3 widescreen Dimming yes Horizontal viewing angle L R typ 80 L R typ 70 Vertical viewing angle U D typ 70 U D typ 60 User memory flash 256MB SD card slot yes Recipe memory Yes Flash memory stora...

Page 10: ...10 Dimensions 7 Dimensions 7 1 HM504 Cutout Model A B C D E F HM504 149mm 109mm 136mm 96mm 56mm 4mm ...

Page 11: ...11 Dimensions 7 2 HM507 HM510 HM513 Cutout Model A B C D E F HM507 187mm 147mm 176mm 136mm 47mm 4mm HM510 287mm 232mm 276mm 221mm 56mm 4mm HM513 336mm 267mm 326mm 256mm 56mm 4mm ...

Page 12: ...rder to meet the front panel degree of protection if the following requirements are met The borders of the cutout must be flat Each fixing screw must be tightened until the plastic bezel corner get in contact with the panel The cutout for the panel must be of the dimensions indicated in this manual The IP66 is guaranteed only if The max deviation from the plane surface to the cut out is 0 5mm The ...

Page 13: ...13 Installation 8 3 Installation procedure Place the fixing brackets as shown in the figure below Make sure to screw each fixing screw until the bezel corner gets in contact with the panel ...

Page 14: ... 1 Serial port 2 2x Ethernet port 3 USB port 4 Power supply 5 Expansion slot for plug ins 6 SD card slot 9 2 HM507 HM510 and HM513 1 Serial port 2 2x Ethernet port 3 2x USB port 4 Power supply 5 2x Expansion slot for plug ins 6 SD card slot ...

Page 15: ...are programmable Make sure you select the appropriate interface in the pro gramming software RS232 RS422 RS485 Pin Description Serial port Pin Description 1 GND 1 GND 2 2 3 TX 3 CHA 4 RX 4 CHB 5 5 6 5V output 6 5V output 7 CTS 7 CHB 8 RTS 8 CHA 9 9 For RS485 pins 4 3 and 8 7 must be connected externally 9 4 Ethernet port The Ethernet ports have two status indicators They work as shown in the pictu...

Page 16: ...only if the plugin module is equipped with the bus extension connector Module Application Max No of plug ins Bus extension connector PLCM03 Serial RS232 2 Yes PLCM04 Serial RS485 2 Yes If you are planning to use PLCM03 and PLCM04 additional serial ports the COM port numbers will be assigned as follows A module plugged in slot 1 or slot 2 will be COM2 A module plugged in slot 3 or slot 4 will be CO...

Page 17: ... block A label helps identify the ground connection Also ground the terminal 3 on the power supply terminal block The power supply circuit may be floating or grounded In the latter case connect to ground the power source common as indicated with a dashed line in the figure below When using the floating power scheme note that internally the power common is connected to the ground with a 1MΩ resisto...

Page 18: ...o local regulations 11 Cleaning faceplates The equipment must be cleaned only with a soft cloth and neutral soap product Do not use solvents 12 Getting started The HM500 series panels must be programmed with the programming software HMWIN Studio a Windows application To program a panel you will have to connect the panel via the Ethernet interface to a personal computer running the HMWIN Studio sof...

Page 19: ...rent version when applicable The picture below shows the version of the Main OS component The system settings tool has two operating modes User mode and System mode The difference between them is only in the number of available options To activate the system settings in user mode you need to access the context menu by touching and holding any unused area of the touchscreen for a few seconds The de...

Page 20: ...anel flash disk Resize Image Area Allows to resize the flash portion reserved to store the splash screen image displayed by the unit at power up default settings are normally ok for all the units Download Configuration OS Allows to check current version and upgrade the backup operating system Download Main OS Allows to check current version and upgrade the main operating system Download Splash Ima...

Page 21: ...able below shows how the LED indicator works Symbol Color State Meaning red ON Hardware fault or battery low green ON Normal operation Flashing Communication error 15 Unpacking and packing instructions 1 2 3 To repack the unit please follow the instructions backwards ...

Page 22: ...ebsite URL Updated back page Distributed by Panasonic Electric Works Europe AG https industry panasonic eu Copyright 2011 2021 Exor International S p A Verona Italy Subject to change without notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it is provided as...

Page 23: ...Via del Commercio 3 5 Z I Ferlina 37012 Bussolengo VR Tel 39 0456752711 Fax 39 0456700444 www panasonic electric works it Nordic Countries Panasonic Electric Works Europe AG Panasonic Fire Security Europe AB Filial Nordic Knarrarnäsgatan 15 164 40 Kista Sweden Tel 46 859476680 Fax 46 859476690 www panasonic electric works se Jungmansgatan 12 21119 Malmö Tel 46 40 697 7000 Fax 46 40 697 7099 www pa...