153
Maintenance and Inspections : Warning System
M
a
int
ena
nc
e and
In
s
pec
tions
10. 1394 Error
Display window
indication
The 1394 E-
¢¢
indicator in the display
window blinks. For more information, see
[
1394 Error Codes
] (page 154).
WARNING lamp
Blinks 4 times per second while the
WARNING lamp recording is continuing.
Tally lamp
Blinks 4 times per second while the TALLY
LAMP recording is continuing.
Viewfinder
In the case of Error Code 92, “1394 INITIAL
ERROR” indicator lights up (during pause
and recording)
For Error Codes other than Error Code 92, or
if REC SIGNAL is set to “1394”, no error is
displayed in the viewfinder.
Warning tone
Beeps 4 times per second while ALARM
recording is continuing.
Warning
description
This indicates a failure of the DVCPRO
connector.
Recording/
playback
operation
The operation continues, but input signals to
the DVCPRO connector are abnormal. For
more information, see [
1394 Error Codes
]
(page 154).
Countermeasures
Check the connection between the
IEEE1394 cable and the DVCPRO
connector, settings of any external device
and menus, and the turn on the power again.
If the warning indication is still illuminated,
confirm the “
1394 Error Codes
” (page 154),
and consult your distributor.
13. P2 Card Error
Display window
indication
Displays “00:00:00:11” in the time code
display. The window continues to flash until
the next operation, even after stopping
record and playback.
WARNING lamp
If the error occurs during recording, the lamp
flashes four times per second for a period of
about three seconds. The lamp does not
light if the error occurs during playback.
Tally lamp
If the error occurs during recording, the lamp
flashes four times per second for a period of
about three seconds. The lamp does not
light if the error occurs during playback.
Viewfinder
A flashing “CARD ERR
¢
” appears. In the
actual indication the
¢
is replaced by the slot
number of the P2 card that triggered the error.
Warning tone
If the error occurs during recording, the tone
sounds four times per second for a period of
about three seconds. The tone does not
sound if the error occurs during playback.
Warning
description
An error has occurred while recording data
to or playing data from a P2 card.
Recording/
playback
operation
Stop recording or playback. After recording
is stopped, the P2 card where error occurs is
write protected.
Countermeasures
Replace the affected P2 card.
11. Battery Nearly Empty
Display window
indication
One of the bars in the battery remaining
indicator starts blinking.
WARNING lamp
Blinks once per second.
Tally lamp
Blinks once per second.
Viewfinder
The BATT LED blinks.
Warning tone
Beeps 4 times per second.
Warning
description
The battery is about to run out.
Recording/
playback
operation
Continues to operate.
Countermeasures
Replace the battery as required.
14. FAN STOP
Display window
indication
No display.
WARNING lamp
Blinks 4 times per second.
Tally lamp
No display.
Viewfinder
The FAN STOP indicator blinks while
recording continues.
Warning tone
It does not sound.
Warning
description
The fan is at rest because something is
wrong with it.
Recording/
playback
operation
If the camera-recorder operates with the fan
stopped, then the temperature inside rises.
While the camera-recorder continues to
operate, clips may not be recorded or played
back properly.
Countermeasures
Immediately stop using the camera-recorder
and consult your distributor.
12. P2 Card Nearly Full
Display window
indication
One of the bars for remaining MEDIA
capacity starts blinking.
WARNING lamp
Blinks once per second while recording
continues.
Tally lamp
Blinks once per second while recording
continues.
Viewfinder
The P2 card remaining capacity indicator blinks.
Warning tone
Beeps once per second while recording
continues.
Warning
description
The total remaining capacity of all the P2
cards is two minutes or less.
Recording/
playback
operation
Continues to operate.
Countermeasures
Replace the cards. If there is an empty card
slot, insert a new card.
15. PROXY CARD ERROR
Display window
indication
No display.
WARNING lamp
Flashes 4 times per second for a period of
about 3 seconds.
Tally lamp
Flashes 4 times per second for a period of
about 5 seconds.
Viewfinder
The “PROXY CARD ERROR” indicator light up.
Warning tone
It does not sound.
Warning
description
Proxy recording stops because of failure on
either the video encoder card or the stream.
Recording/
playback
operation
The unit continues to operate.
Countermeasures
Check the video encoder card or avoid use
of proxy recording.
AJ-HPX3000G(VQT1K82-5)E.book 153 ページ 2009年11月12日 木曜日 午後8時19分