154
Maintenance and Inspections : Warning System
The following error codes are displayed in the display window if an error occurs in the camera:
Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 151) for countermeasures.
Error Codes
Code No.
Description
Type of warnings
E-11
Video initialisation error
1. System Errors
E-27
Recording control error
1. System Errors
E-30
P2 card removal error
2.
Card removal error
E-34
LCD microcontroller error
1. System Errors
E-38
P2 streaming microcontroller error
1. System Errors
E-39
Abnormal initialization of the AVC-Intra codec board
1. System Errors
E-3F
Microprocessor error in the camera control circuit.
1. System Errors
E-40
Image sequence or GENLOCK input signal error (in case of 24P, 30P and
25P)
6. Image Sequence Error (24P, 30P, 25P)
E-63
Something is wrong with the system control microprocessor.
1. System Errors
E-6F
Reference signal error.
1. System Errors
00:00:00:11
Errors such as recording to P2 card error
7. Recording Error, 8. Number of Clips
Exceeded, 13. P2 Card Error
1394 Error Codes
Code No.
Description
Recording
Indication in display
window
1394 E-80
Signals being input to the DVCPRO connector
are not 1
a
speed transfer signals in DV format.
Stops
1394 E-81
Signals being input to the DVCPRO connector
are not 1
a
speed transfer signals in DVCPRO
(25 Mbps) format.
Stops
1394 E-82
Signals being input to the DVCPRO connector
are not 1
a
speed transfer signals in
DVCPRO50 (50 Mbps) format.
Stops
The time code section of the
display window indicates the
appropriate error code that
blinks every two seconds.
1394 E-83
Incorrect signals are being input to the
DVCPRO connector.
Stops
1394 E-84
Signals being input to the DVCPRO connector
are not in DVCPRO or DV format.
Stops
1394 E-85
Signals being input to the DVCPRO connector
are not 1x speed transfer signals in DVCPRO
HD format.
Stops
1394 E-87
Incorrect audio signals are being input to the
DVCPRO connector.
Continues with no sound.
1394 E-90
No signal is supplied to the DVCPRO
connector.
While the recording mode
continues, no data is recorded on
cards unless the abnormal
condition is corrected. If an error
has occurred before recording,
then, recording does not start.
1394 E-91
With the menu option REC MODE set to DV,
copy guard information signals for recording
prohibited data are being input to the DVCPRO
connector.
Stops
1394 E-92
The DVCPRO connector is not properly
connected. The viewfinder indicates the
message "1394 INITIAL ERROR."
No recording in 1394 input mode
can be performed.
AJ-HPX3000G(VQT1K82-5)E.book 154 ページ 2009年11月12日 木曜日 午後8時19分