2.4 Fault Recovery/Diagnostics
2.4.1 Power Failure Transfer
Description
When the power supply to the PBX fails, specific SLTs and/or ISDN terminal devices are automatically
connected to specific trunks (
Power Failure Connections
). The PBX will switch from normal operation to the
Power Failure Connections, and all existing conversations will be disconnected.
Only the trunks handled by Power Failure Connections can be used during a power failure.
Conditions
[General]
•
Only trunk calls can be made during a power failure. All other features do not work.
•
DC Power Source
If the DC power is available from backup batteries, even if the AC power fails, the PBX will remain fully
operational.
[KX-TDA600]
•
The analogue trunk cards and extension cards, as well as the number of PFT ports (ports which can be
used for Power Failure Connections) are as follows:
Trunk Cards:
ELCOT16 (4 PFT ports)
Extension Cards:
ECSLC24 (4 PFT ports), EMSLC16 (4 PFT ports), CSLC16 (4 PFT ports), ESLC16 (4
PFT ports), DHLC8 (2 PFT ports), SLC8 (2 PFT ports)
Only connect one extension card to each trunk card.
Note
Power Failure Connections must be made within the same shelf. An extension card cannot have a
Power Failure Connection with a trunk card of another shelf.
Through system programming, it is possible to allow trunk calls that are established during a power
failure to be maintained even when the power returns and the connection is switched back to the normal
configuration from the Power Failure Connection. However, if no special programming is performed,
the connection will be dropped when power returns.
•
The BRI8 (one PFT port) and BRI4 (one PFT port) cards can also be used for Power Failure Connections.
For details about Power Failure Connections, refer to the Installation Manual.
[KX-TDA100/KX-TDA200]
•
The analogue trunk cards and extension cards, as well as the number of PFT ports (ports which can be
used for Power Failure Connections) are as follows:
Trunk Cards:
LCOT16 (4 PFT ports), LCOT8 (2 PFT ports), and LCOT4 (2 PFT ports)
Extension Cards:
MSLC16 (4 PFT ports), CSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT
ports) and SLC8 (2 PFT ports)
Only connect one extension card to each trunk card.
Note
Through system programming, it is possible to allow trunk calls that are established during a power
failure to be maintained even when the power returns and the connection is switched back to the normal
Feature Guide
425
2.4.1 Power Failure Transfer
Summary of Contents for HYBRID IP-PBX KX-TDA200
Page 15: ...Section 1 Call Handling Features Feature Guide 15...
Page 91: ...User Manual References 1 2 1 Basic Calling Feature Guide 91 1 5 4 Trunk Call Features...
Page 113: ...User Manual References 1 2 2 Easy Dialling Feature Guide 113 1 6 1 Memory Dialling Features...
Page 156: ...3 1 2 Settings on the Programming Mode 156 Feature Guide 1 11 4 Headset Operation...
Page 175: ...User Manual References 1 4 2 Holding a Call Feature Guide 175 1 13 1 Call Hold...
Page 385: ...Section 2 System Configuration and Administration Fea tures Feature Guide 385...
Page 430: ...430 Feature Guide 2 4 3 Local Alarm Information...
Page 431: ...Section 3 Appendix Feature Guide 431...
Page 456: ...456 Feature Guide 3 4 13 KX TDA30 PSMPR Software File Version 5 0xxx...
Page 457: ...Index Feature Guide 457...
Page 463: ...Feature Guide 463 Notes...