Temporary placement
Before installing the window/door sensor, temporarily place it in the desired
location and confirm that it operates properly by pressing
M
N
.
Important:
R
Attach the sensor unit to the window frame or door frame, and attach the
magnet unit to the window or door.
R
The window/door sensor will not operate properly if the “ ” marks are too far
apart or are not pointing toward each other.
R
Attach both units so that the “ ” marks point toward each other and are within
25.4 mm of each other.
Confirming proper operation
After temporarily placing the window/door sensor in the desired location, press
M
N
while the window or door is closed. The window/door sensor’s LED indicator
lights as follows.
Indicator
Status
Green, lit
The installation position is correct.
Red, lit
The “ ” marks on the sensor unit and the magnet unit
are too far from each other. Re-attach the sensor unit
and the magnet unit so that they point directly at each
other and are no more than 25.4 mm apart.
Red, blinking
The sensor unit is out of range of the hub. Refer to the
information on page 10.
Note:
R
Depending on the condition and material of the surface where the sensor unit
and magnet unit are installed, the LED indicator may light in red even if the “ ”
marks point directly at each other and are no more than 25.4 mm apart.
11
Setup
Summary of Contents for KX-HNS101FX
Page 19: ...19 Notes ...