Q
I changed the FCO of a Portable Station, but the display of the Portable Station still
shows the old FCO.
A
•
Turn the Portable Station off and back on again, to force it to re-register its location.
Q
If I delete the extension number of a Portable Station, and then turn the Portable
Station off and back on again, it does not function correctly.
A
•
Do not delete the extension number of the Portable Station, as this information is
necessary for it to operate.
Numbering
Q
How do I change the extension number of a wired extension?
A
•
Change the extension number of the target port to the new number, and click
Apply
.
Next, set the port to OUS status, and then back to INS status.
Q
I changed the extension number of a wired extension while the extension was
engaged in a call, but the display still shows the previous extension number.
A
•
The extension number will not change while the extension is in use. When the
conversation is finished, set the port to OUS status, and then back to INS status.
Q
How do I change the extension numbering plan from 3-digit numbers to 4-digit
numbers?
A
•
Perform the following steps:
1.
Open the
4.9 [2-6-1] Numbering Plan—Main
screen.
2.
Enter a 2-digit number in
Leading Number
, or change
No. of Additional
Digits
from "x" to "xx".
For more details, see
What is the procedure to modify the Numbering Plan?
in
Numbering
.
Q
How do I set a 3-digit numbering plan?
A
•
There are 2 methods of creating a 3-digit numbering plan, using
4.9 [2-6-1]
Numbering Plan—Main
:
1.
Set the leading number to be 2 digits, with one additional digit. This method allows
a maximum of 10 extensions.
Example:
Leading Number = 10;
No. of Additional Digits
= x
In this example, extension numbers 100 to 109 can be used.
2.
Set the leading number to be one digit, with 2 additional digits. This method allows
a maximum of 100 extensions.
Example:
Leading Number
= 1;
No. of Additional Digits
= xx
In this example, extension numbers 100 to 199 can be used.
For more details, see
What is the procedure to modify the Numbering Plan?
in
Numbering
.
Q
What is the procedure to modify the Numbering Plan?
PC Programming Manual
99
2.7.1 Frequently Asked Questions (FAQ)
Summary of Contents for KX-NCP1000
Page 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters ...
Page 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters ...
Page 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters ...
Page 106: ...106 PC Programming Manual 2 7 1 Frequently Asked Questions FAQ ...
Page 107: ...Section 3 1 Configuration PC Programming Manual 107 ...
Page 461: ...Section 4 2 System PC Programming Manual 461 ...
Page 594: ...594 PC Programming Manual 4 21 2 11 2 Audio Gain Card ...
Page 595: ...Section 5 3 Group PC Programming Manual 595 ...
Page 615: ...2 2 3 Tenant Service PC Programming Manual 615 5 7 3 2 User Group ...
Page 673: ...Section 6 4 Extension PC Programming Manual 673 ...
Page 811: ...Section 7 5 Optional Device PC Programming Manual 811 ...
Page 839: ...Section 8 6 Feature PC Programming Manual 839 ...
Page 859: ...Section 9 7 TRS PC Programming Manual 859 ...
Page 867: ...Section 10 8 ARS PC Programming Manual 867 ...
Page 879: ...Section 11 9 Private Network PC Programming Manual 879 ...
Page 892: ...892 PC Programming Manual 11 4 9 4 NDSS Key Table ...
Page 893: ...Section 12 10 CO Incoming Call PC Programming Manual 893 ...
Page 922: ...922 PC Programming Manual 12 7 10 5 Miscellaneous ...
Page 923: ...Section 13 11 Maintenance PC Programming Manual 923 ...
Page 961: ...Section 14 Appendix PC Programming Manual 961 ...
Page 974: ...974 PC Programming Manual 14 1 8 KX TDE600 PGMPR Software File Version 4 1xxx ...
Page 975: ...Feature Programming References PC Programming Manual 975 ...