Application
LAN Side Port Number
WAN Side Port Number
NTP
NAT - NTP Server Port No.
(Use the same value as in step
of
*1
The port number for NTP that the KX-NS300 uses is fixed to 123.
Note
For information about configuring port forwarding on the router, refer to the documentation of the router.
Installing KX-UT series SIP phones at a remote site
There are 2 methods to install KX-UT series SIP phones at a remote site:
•
Set up KX-UT series SIP phones at the main site using the KX-NS300, and then send them to the remote
site.
•
Set up KX-UT series SIP phones without connecting them to the KX-NS300 at the main site, and then send
them to the remote site.
Setting up KX-UT series SIP phones at the main site, and then sending them to remote site
1.
Register the KX-UT series SIP phone. For details, refer to "5.8.1 Registering IP Telephones".
2.
Program the settings for the KX-UT series SIP phones.
a.
Click
Setup
®
PBX Configuration
®
Configuration
®
Slot
.
b.
Place the mouse cursor over the
Virtual Slot
, and in the menu that appears, click
Select Shelf
.
c.
Move the mouse pointer over the V-UTEXT8 card (Virtual UT Extension Card).
A menu will be shown under the mouse pointer.
d.
Click
Port Property
.
e.
Click
Remote Place
tab.
f.
Configure the items shown below.
•
Select a protocol (HTTP/HTTPS) for
Protocol for Remote SIP-MLT
.
Note
When a SIP phone at remote site uses the internet to communicate with a KX-NS300 , use the
HTTPS protocol for security. If the connection is on VPN and protected, you may use the HTTP
protocol.
•
Change the value to
Remote (SBC)
for
Phone Location
.
g.
Click
OK
.
3.
Unplug the AC adaptor of the KX-UT series SIP phone, and then plug it in again to reboot the KX-UT series
SIP phone manually.
The KX-UT series SIP phone will download settings automatically.
Note
•
After downloading the setting information for the remote site, the KX-UT series SIP phone will not
connect to the KX-NS300 if it is connected to the LAN at the main site. After some time, the
KX-UT series SIP phone will display "9002: Connection Failed".
•
Depending on the settings of your router, the KX-UT series SIP phone may connect to the PBX. In
such cases, proceed to step
.
4.
Send the KX-UT series SIP phone to the remote site and connect it to the LAN in the remote site.
Note
The KX-UT series SIP phone is already registered to the KX-NS300 and programmed with the remote
site configuration. There is no operation required for the KX-UT series SIP phone at the remote site.
230
Installation Manual
5.8.3 Installing SIP Phones at a Remote Site
Summary of Contents for KX-NS300
Page 92: ...4 Hook the main unit on the screw heads 92 Installation Manual 4 2 10 Wall Mounting...
Page 150: ...150 Installation Manual 4 13 Starting the KX NS300...
Page 248: ...248 Installation Manual 5 11 Automatic Configuration of Mailboxes...
Page 252: ...252 Installation Manual 6 1 Methods of Stacking Expansion Units...
Page 294: ...294 Installation Manual 8 5 Port Security...
Page 298: ...298 Installation Manual 9 2 System Prompt Languages...
Page 299: ......