2.3 Specifications
2.3.1 General Description
KX-NS300
Main CPU
Cortex A8 600 MHz
Power Input
100 V AC to 130 V AC: 2.2 A/200 V AC to 240 V AC: 1.3 A;
50 Hz/60 Hz
Power Consumption (when fully
mounted)
110 W
External Backup Battery
External battery port is supported.
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID (FSK/DTMF)
1600
W
Maximum
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling with Caller ID (FSK/DTMF)
Port 1-2 (on pre-installed MCSLC16) support PFT in
combination with the port 1-2 (on pre-installed LCOT6)
connected to an analogue trunk respectively.
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
Conference Call Trunk
From 10
´
3-party conference call to 4
´
8-party conference call
Music on Hold (MOH)
Maximum 8 ports (Level Control: 31.5 dB to +31.5 dB per 0.5
dB)
MOH: Selectable Internal/External Music Source Port
External Paging
Maximum 6 Ports (Volume Control: -15.5 dB to per 0.5 dB)
LAN Port
1 (for LAN connection)
10BASE-T/100BASE-TX
(Auto MDI/MDI-X)
Extension Connection Cable
SLT
1-pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
PT-interface CS (High-density)
4-pair wire (D1, D2)
DSS Console and Add-on Key
Module
1-pair wire (D1, D2)
Air-cooling method
FAN
Dimension
430 mm (W)
´
88 mm (H)
´
367 mm (D)
32
Installation Manual
2.3.1 General Description
Summary of Contents for KX-NS300
Page 92: ...4 Hook the main unit on the screw heads 92 Installation Manual 4 2 10 Wall Mounting...
Page 150: ...150 Installation Manual 4 13 Starting the KX NS300...
Page 248: ...248 Installation Manual 5 11 Automatic Configuration of Mailboxes...
Page 252: ...252 Installation Manual 6 1 Methods of Stacking Expansion Units...
Page 294: ...294 Installation Manual 8 5 Port Security...
Page 298: ...298 Installation Manual 9 2 System Prompt Languages...
Page 299: ......