General Installation

36

Installation Manual

If the reading is not obtained the outlet is not adequately grounded, see a qualified 
electrician.

Summary of Contents for KX-T7020

Page 1: ...Model No KX TA1232 Advanced Hybrid System Installation Manual A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic Please read this manual before connecting the Advanced Hybrid System ...

Page 2: ...line of VPS products Its release is due in the summer of 2001 It has 4 ports and 20 hours of recording time It could be perfect for your demanding office needs Custom Service can effectively distribute incoming calls by user recorded menus in any language you like Callers can be automatically directed to extensions mailboxes the fax machine etc by single digit entries You can record up to 100 menu...

Page 3: ...7055 Proprietary telephone with backlit display Proprietary telephone with display Proprietary telephone Proprietary telephone with display Proprietary telephone Proprietary telephone Optional Equipment KX T7040 DSS Console KX TA123260 KX TA123270 KX TA123280 KX TA123291 KX TA123293 Doorphone Door Opener Interface Card 8 Extension Expansion Unit 4 CO Line Expansion Unit DISA Card Caller ID Card KX...

Page 4: ...ot sure of the type of power supply to your home consult your dealer or local power company h This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat...

Page 5: ...ge and will often require extensive work by a qualified technician to restore the product to normal operation 5 If the product has been dropped or the cabinet has been damaged 6 If the product exhibits a distinct change in performance n Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning o Do not use the telephon...

Page 6: ...n authorized Panasonic Factory Service Center If the telephone does not operate properly chances are that the trouble is in the telephone system and not in the unit Do not use benzine thinner or the like or any abrasive powder to clean the cabinet Wipe it with a soft cloth WARNING THIS UNIT MAY ONLY BE INSTALLED AND SERVICED BY QUALIFIED SERVICE PERSONNEL WHEN A FAILURE OCCURS WHICH RESULTS IN THE...

Page 7: ...eferably in the original carton Attach a postage paid letter detailing the symptom to the outside of the carton DO NOT send the product to the Executive or Regional Sales offices They are NOT equipped to make repairs Product service Panasonic Factory Servicenters for this product are listed in the servicenter directory Consult your authorized Panasonic dealer for detailed instructions Part No Pict...

Page 8: ...f the unit You should note the model number and the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid in identification in the event of theft MODEL NO SERIAL NO DATE OF PURCHASE NAME OF DEALER DEALER S ADDRESS DEALER S TEL NO For your future reference ...

Page 9: ...mer that temporary discontinuance of service may be required However where prior notice is not practical the telephone company may temporarily discontinue service forthwith if such action is reasonable in the circumstances In case of such unnotified temporary discontinuance of service the telephone company shall 1 Promptly notify the customer of such temporary discontinuance of service 2 Afford th...

Page 10: ...k Interface Jack RJ11 14C RJ49 Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not inst...

Page 11: ...elp you access the required information easily Programming Guide References The related and required programming titles described in the Programming Guide are noted for your reference Programming Guide reference is also shown in the sentences as follows Example SYS PRG 109 Explanation Refer to system program 109 in the Programming Guide This helps you know the related and required programming easi...

Page 12: ...nnection 37 2 3 1 Outside Line Connection 37 2 3 2 Extension Connection 38 2 3 3 Telephone Connection 43 2 3 4 Polarity Sensitive Telephone Connection 45 2 3 5 External Pager Paging Equipment Connection 47 2 3 6 External Music Source Connection 48 2 3 7 Printer and PC Connection 50 2 3 8 Installation of Lightning Protectors 54 2 4 Installation of Optional Cards and Units 57 2 4 1 Location of Optio...

Page 13: ...em for the First Time 82 2 8 System Restart 84 2 8 1 System Restart 84 2 9 System Data Clear 85 2 9 1 System Data Clear 85 3 Troubleshooting 3 1 Troubleshooting 88 3 1 1 Installation 88 3 1 2 Connection 89 3 1 3 Operation 91 3 1 4 Using the Reset Button 92 Index 95 ...

Page 14: ...Table of Contents 14 Installation Manual ...

Page 15: ...System Outline Installation Manual 15 Section 1 System Outline This section provides general information on the system including system capacity and specifications ...

Page 16: ...tem This system supports the connection of analog proprietary telephones a DSS Console and single line devices such as single line telephones fax machines and data terminals Analog Proprietary Telephones APT The system supports six different models of analog proprietary telephones Programming System The system can be programmed from a proprietary telephone Voice Mail Integration The system support...

Page 17: ...f a caller on the telephone display before answering a call Trunk Outside Line Answer From Any Station TAFAS Ringing occurs over the external paging system the call can be answered from any station Remote Station Lock Control Allows an operator to lock an extension so that outgoing calls cannot be made ...

Page 18: ...extensions It is capable of supporting Panasonic analog proprietary telephones a DSS Console and single line devices such as single line telephones and fax machines To expand its capabilities the system can be equipped with optional components or customer supplied peripherals such as external speakers and external music sources e g radios A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic ...

Page 19: ... KX TA1232 Panasonic Printer or PC for SMDR Station Message Detail Recording AC Surge Protector 120 V AC 60 Hz Avoid using the same AC outlet for office equipment and the KX TA1232 Use a dedicated AC outlet only External Music Source 1 External Music Source 2 Amplifier Speaker 1 Amplifier Speaker 2 ...

Page 20: ... 1 through 8 initial to outside lines 9 through 12 additional 12 Outside Lines 32 Extensions 16 extensions initial 16 extensions additional Cordless Phone one pair two pair KX T7040 two pair one pair one pair one pair one pair KX T7030 two pair two pair two pair KX T7130 KX T7135 Telephone Answering Machine with Facsimile Voice Processing System D1232 DEGITAL SUPER HYBRID SYSTEM Panasonic KX T7020...

Page 21: ...lexible CO button programmable PF Programmable Feature button Proprietary Telephone Description KX T7135 1 line backlit display speakerphone 12 Flexible CO 12 PF KX T7130 1 line display speakerphone 12 Flexible CO 12 PF KX T7020 Speakerphone 12 Flexible CO 4 PF KX T7030 1 line display speakerphone 12 Flexible CO 4 PF KX T7050 Monitor 12 Flexible CO 4 PF KX T7055 Monitor 3 Flexible CO 3 PF ...

Page 22: ...123291 DISA Card Supports the Direct Inward System Access DISA feature and records outgoing messages 1 KX TA123293 Caller ID Card Supports the Caller ID Service of the central office 3 KX TA123260 Doorphone Door Opener Interface Card Supports 4 doorphones and 4 door openers 1 KX T7040 DSS Console Provides easy and quick access to extensions and features This must be used with a proprietary telepho...

Page 23: ...f Dialing Outward Dial Pulse DP 10 pps 20 pps Tone DTMF Dialing Internal Dial Pulse DP 10 pps 20 pps Tone DTMF Dialing Connectors Outside lines Modular Jack RJ14C Extensions Amphenol Connector Paging Output Pin Jack RCA JACK External Music Input Two conductor Jack MINIJACK 3 5 mm diameter Extension Connection Cable Single line telephones 1 pair wire T R KX T7135 KX T7130 KX T7020 KX T7030 KX T7050...

Page 24: ...or single line telephone 2 by Parallel Connection of a proprietary telephone and a single line telephone Ring Voltage 70 Vrms at 20 Hz depending on the Ringing Load Central Office Loop Limit 1 600 max Environmental Requirements 0 C 40 C 32 F 104 F 10 90 relative humidity Hookswitch Flash Timing Range 200 ms 1000 ms Door Opener 30 V DC 5 A Max 250 V AC 5 A Max Dimensions W x H x D 325 mm x 640 mm x...

Page 25: ...uantity on KX TA1232 Doorphones 4 Door Openers 4 External Pagers 2 External Music Sources 2 Item Max Quantity Operators 2 System Speed Dialing 500 One Touch Dialing 24 per extension proprietary telephone Personal Speed Dialing 10 per extension Call Park areas 10 Absent Messages 9 Outside Line Groups 8 Toll Restriction Levels 8 Extension Groups 8 Class of Service levels 8 Message Waitings 128 ...

Page 26: ...System Outline 26 Installation Manual ...

Page 27: ...General Installation Installation Manual 27 Section 2 General Installation ...

Page 28: ...In direct sunlight and hot cold or humid places Temperature range 0 C 40 C 32 F 104 F b Sulfuric gases produced in areas where there are thermal springs etc may damage the equipment or contacts c Places in which shocks or vibrations are frequent or strong d Dusty places or places where water or oil may come into contact with the system e Near high frequency generating devices such as sewing machin...

Page 29: ...ietary telephones e g KX T7135 KX T7130 f The Power Switch of the system must be off during wiring After all of the wiring is completed turn the Power Switch on g Mis wiring may cause the system to operate improperly Refer to 3 1 1 Installation and 3 1 2 Connection h If an extension does not operate properly disconnect the telephone from the extension line and then connect again or turn off the Po...

Page 30: ...2 2 Installation of the Main Unit 2 2 1 Unpacking Unpack the box and check the items below KX TA1232 Main Unit one AC Cord one Template one Screws Wall Mounting four Pager Connectors two Music Source Connectors two Expansion Line Cord Holder one ...

Page 31: ...ANCED HYBRID SYSTEM KX TA1232 Panasonic Serial Interface RS 232C Connector Ground Terminal AC Inlet Power Switch Power Indicator DISA DOORPHONE Outside Line Modular Jacks Extension Amphenol Connector Paging Jack 2 Paging Jack 1 External Music Jack 2 External Music Jack 1 System Clear Switch Reset Button ...

Page 32: ... support the weight of the main unit If screws other than the ones supplied are used use screws with the same diameter as the ones enclosed Mounting on Wooden Wall 1 Place the template included on the wall to mark the screw positions 2 Install the screws included into the wall 3 Hook the main unit on the screw heads Template Drive the screw to this position Wooden Wall ...

Page 33: ... mark the screw positions 2 Drill holes and drive the anchor plugs user supplied with a hammer flush to the wall 3 Install the screws included into the anchor plugs 4 Hook the main unit on the screw heads Template Concrete Wall To the wall surface Anchor Plug 29 mm 1 1 8 inch 6 4 mm 1 4 inch Drive the screw to this position ...

Page 34: ... the right side of the main unit 2 Open the front cover in the direction of arrow Note The two screws are attached to the front cover with springs so that they will not be lost A Panasonic D816 DIGITAL SUPER HYBRID SYSTEM A screw screw A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic A screw screw ...

Page 35: ...voltage points on the wall outlet The reading obtained should be 108 V AC 132 V AC 3 Move one of the meter probes to the 3rd prong terminal GND Either the same reading or a reading of 0 V should be obtained 4 If a reading of 0 V at one terminal and a reading of 108 V AC 132 V AC at the other terminal is not obtained the outlet is not properly grounded This condition should be corrected by a qualif...

Page 36: ...General Installation 36 Installation Manual If the reading is not obtained the outlet is not adequately grounded see a qualified electrician ...

Page 37: ... Notice Use twisted pair cable for installation It is recommended to use RJ14C telephone jacks Mis connection may cause the system to operate improperly See 3 1 1 Installation and 3 1 2 Connection DISA DOORPHONE Outside Line 1 Outside Line 2 Outside Line 3 Outside Line 4 Outside Line 5 Outside Line 6 Outside Line 7 Outside Line 8 T1 R1 T2 R2 R Ring T Tip T2 R1 T1 R2 View of TEL Jack Outside Line U...

Page 38: ... extension as listed below There are four pins for possible connection T R L and H T Tip R Ring L Low H High Diameter of the line Max length Single Line Telephone 22 AWG 24 AWG 26 AWG 1798 m 5900 feet 1128 m 3700 feet 698 m 2290 feet Proprietary Telephone DSS Console 22 AWG 24 AWG 26 AWG 360 m 1180 feet 229 m 750 feet 140 m 460 feet Telephone Wiring Single line telephones wiring 1 pair wire T R An...

Page 39: ...eral Installation Installation Manual 39 2 pair twisted cabling 50 Pin Connector Block Terminal 1 2 3 4 5 6 26 1 27 2 28 3 6 5 4 3 2 1 Green Red Black Yellow White Blue 1 2 3 4 5 6 Line cord Bridging Clips ...

Page 40: ...rds to the appropriate connector pins and the terminal equipment Refer to the Telephone Wiring Page 38 and Pin Number Chart Page 41 3 After inserting the connector fasten the connector with the nylon tie DISA DOORPHONE 25 50 1 26 Connector type 50 pin Amphenol 57JE series or the equivalent To extensions Jacks 9 16 To extensions Jacks 1 8 ...

Page 41: ...ck No 19 T R L H Jack No 27 T R L H 35 10 36 11 RED SLT SLT RED BLK BLU BLU BLK Jack No 4 T R L H Jack No 12 T R L H Jack No 20 T R L H Jack No 28 T R L H 38 13 39 14 BLK GRN GRN BLK BLK BRN BRN BLK Jack No 5 T R L H Jack No 13 T R L H Jack No 21 T R L H Jack No 29 T R L H 41 16 42 17 YEL BLU BLU YEL YEL ORN ORN YEL Jack No 6 T R L H Jack No 14 T R L H Jack No 22 T R L H Jack No 30 T R L H 44 19 4...

Page 42: ...onsole KX T7040 can be installed As the DSS Console itself cannot work alone it always requires a proprietary telephone used in pair Place the DSS Console and the paired telephone side by side on your desk It is necessary to designate the jack numbers of paired DSS Consoles and proprietary telephones by system programming After completing all the required inside cabling including outside lines ext...

Page 43: ...e Connection Connect proprietary telephones and a DSS Console as follows Analog Proprietary Telephone KX T7040 DSS Console Included telephone line cord Connect to an Advanced Hybrid System TO EMSS Connect to an Advanced Hybrid System TO EMSS Included telephone line cord ZU R ZE NT RA LE P a n a s o n i c ...

Page 44: ...s Method Using a Modular T Adaptor Any single line telephone can be connected in parallel with a proprietary telephone as follows Modular T Adaptor Panasonic KX J66 or USOC RJA2X 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord For APT Connect pins T2 R L and H A1232 ADVANCED HYBRID SYSTEM KX TA1232 Analog Proprietary Telephone Single Line Telephone ...

Page 45: ...n and the system must be reversed 3 Reverse as shown 4 Set the Power Switch to OFF position 5 Connect all outside lines 6 Confirm that dialing can be done on the following extensions using a tone telephone Extension T R of jack 1 Outside line 1 Extension T R of jack 9 Outside line 3 Extensions T R of jacks 17 Extension Expansion Unit 1 Outside line 9 If dialing fails the polarity between the syste...

Page 46: ...n 46 Installation Manual 7 Reverse as shown 8 Every time an extension telephone is replaced repeat the above procedure A1232 ADVAVNCED HYBRID SYSTEM KX TA1232 1 2 3 4 5 6 7 8 9 0 Central Office Line Reverse here Extension ...

Page 47: ...is programmable which external pager will send background music and whether all the pagers will generate a confirmation tone To adjust the sound level of the pagers use the volume control on the amplifiers Programming Guide Reference 804 External Pager BGM 805 External Pager Confirmation Tone Features Guide Reference Background Music BGM Paging All Trunk Outside Line Answer From Any Station TAFAS ...

Page 48: ...ug 3 5 mm 9 64 inch in diameter Input impedance 8 Maximum length of the cable AWG 18 22 Under 10 m 33 feet Note System Programming of music sources used for Music on Hold and Background Music is required To adjust the sound level of the Music on Hold use the volume control on the external music source Programming Guide Reference 803 Music Source Use 990 System Additional Information DISA DOORPHONE...

Page 49: ...General Installation Installation Manual 49 Features Guide Reference Background Music BGM Background Music BGM External Music on Hold ...

Page 50: ...inter cable or the PC cable to the Serial Interface RS 232C connector The cable must be shielded and the maximum length is 2 m 6 5 feet Note Arrange cables so that the printer will be connected to the system as shown in the chart on the following page When using special accessories such as cable the user should use those specified in this installation manual to comply with the limits for a class A...

Page 51: ...RS RTS Received Data Request To Send BB CA 104 105 5 6 CS CTS DR DSR Clear To Send Data Set Ready CB CC 106 107 7 8 SG CD DCD Signal Ground Data Carrier Detect AB CF 102 109 20 ER DTR Data Terminal Ready CD 108 2 1 IBM is a registered trademark of International Business Machines Corporation Circuit Type EIA Signal Name Pin No AA BA FG SD TXD RD RXD CS CTS CR DSR SG ER DTR Signal Name FG RD RXD SD ...

Page 52: ...e printer is ready to receive data from the unit The unit does not attempt to transfer data or receive data when circuit CS CTS is OFF Data Set Ready DR DSR input An ON condition of circuit DR DSR indicates the printer is ready Circuit DR DSR ON does not indicate that communication has been established with the printer Signal Ground SG Connects to the DC ground of the unit for all interface signal...

Page 53: ...is an indication to data terminal DTE that the carrier signal is being received Programming Guide Reference 800 SMDR Incoming Outgoing Call Log Printout 801 SMDR Format 802 System Data Printout 806 Serial Interface RS 232C Parameters Features Guide Reference Station Message Detail Recording SMDR ...

Page 54: ...re are regulations requiring the installation of a lightning protector A lightning strike to a telephone cable which is 10 m 33 feet above ground can be as high as 200 000 V This system should be installed with lightning protectors In addition grounding connection to earth ground is very important for the protection of the system Recommended lightning protectors TELESPIKE BLOK MODEL TSB TRIPPE MFG...

Page 55: ...llowing precautions are recommended a Install the extension wire underground b Use a conduit to protect the wire Note The lightning protector for an extension is different from that for outside line Main Building CO Another Building CO CO Ter minal Board Main Unit Protectors EXTN TEL TEL EXTN SLT PT EXTN Lightning Protector EXTN Ground ...

Page 56: ...e earth rod Metal 4 Depth of the earth rod More than 50 cm 20 inches 5 Size of the grounding wire Thickness is more than 16 AWG 6 Length of the grounding wire As short as possible Note The above figures are recommendations only The length of earth rod and the required depth depend on the composition of the soil Lightning Protector CO Main Unit Grounding Wire Underground Earth Rod ...

Page 57: ...tatic electricity do not touch parts on the P boards in the main unit and on the optional cards Expansion Units The following expansion units can be installed to any of the three expansion areas Expansion area 2 Expansion area 3 Expansion area 1 Expansion Unit Connectors Remove the cover plate s on the front cover 8 Extension Expansion Unit KX TA123270 4 CO Line Expansion Unit KX TA123280 Max two ...

Page 58: ...d 3 8 Extension Expansion Unit DISA Card Doorphone Door Opener Interface Card DISA DOORPHONE DISA Card Connector Doorphone Door Opener Interface Card Connector Front Cover is open Install DISA Card KX TA123291 This card permits access to the system from outside tone telephones Install Doorphone Door Opener Interface Card KX TA123260 This card connects four doorphones and four door openers ...

Page 59: ...e Expansion Unit This card supports Caller ID services offered by the central office The initially provided Outside Line Card is located behind the inside cover 4 CO Line Expansion Unit KX TA123280 inside the cabinet Install one Caller ID Card KX TA123293 4CO AD VA NC ED HY BR ID SY ST EM Initial Outside Line Card Install up to two Caller ID Cards KX TA123293 Inside cover ...

Page 60: ...as provided on the front of the main unit For outside line expansion unit installation see 2 4 4 Installing Expansion Unit Note System Programming is required for card location identification If you intend to attach a Caller ID Card to the 4 CO Line Expansion Unit attach the Caller ID Card before outside line connection See 2 4 6 Caller ID Card Installation Programming Guide Reference 109 Expansio...

Page 61: ... 16 extensions jack numbers 17 through 32 use two 8 Extension Expansion Units This unit can be installed to any of the expansion unit areas provided on the front of the main unit For extension expansion unit installation see 2 4 4 Installing Expansion Unit Note System Programming is required for card location identification Programming Guide Reference 109 Expansion Unit Type Features Guide Referen...

Page 62: ...0 are the same for all expansion units Step 6 is different for each unit 1 Loosen the two screws on the cover plate Insert fingers into the slits to remove the cover plate Note Any of the cover plates can be removed as needed 2 Connect the cabinet cord to the connector in the main unit firmly Slit Slit A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic Panasonic A1232 ADVANCED HYBRID SYSTEM KX TA123...

Page 63: ...nd slide the cover to the right 5 Secure the inside screw included to fix the cabinet to the main unit Note Be sure to fix the inside screw to the main unit or the unit may not work properly Panasonic A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic A1232 ADVANCED HYBRID SYSTEM KX TA1232 Outside screw Inside screw Panasonic A1232 ADVANCED HYBRID SYSTEM KX TA1232 ...

Page 64: ...r jacks on the unit Note For details refer to 2 5 1 Auxiliary Connection for Power Failure Transfer To Terminal Board or Modular Jacks from the Central Office P anasonic 4C O A D V A N C E D H Y B R ID S Y S TE M P FT ports 2C O w P FT 2C O R Ring T Tip T2 R1 T1 R2 View of TEL Jack Outside Line T1 R1 T2 R2 Outside Line 9 Outside Line 10 Outside Line 11 Outside Line 12 Jack for Power Failure Transf...

Page 65: ...to be connected see Pin Number Chart in 2 3 2 Extension Connection For fixing the connector see Amphenol 57JE Type screw attach type 50 pin connector Connection for KX TA123270 in 2 4 4 Installing Expansion Unit To extensions Jacks 17 24 or 25 32 P anasonic 8E X T AD VA N C ED H YB R ID SY ST EM PF T po rts 8E XT 25 50 1 26 Connector type 50 pin Amphenol 57JE series or the equivalent Jack for Powe...

Page 66: ...upper cabinets tie them also 8 Close the cabinet cover and secure the outside screw 9 Cover the cords with the cord holder included 10 Fix the cords to the wall as shown so that the front cover can be opened Cord holder A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic ...

Page 67: ...ach it before installing the 4 CO Line Expansion Unit to the main unit For installation Refer to 2 4 6 Caller ID Card Installation If two expansion units are installed cut the cabinet cover s on the lower cabinet s to allow the cords from upper cabinet to go down through the cabinet cover s To protect the cords smooth the cut edges Cut here ...

Page 68: ...Expansion Unit follow the procedure below 1 The 50 pin connector Jack on the Expansion Unit has two hook pins Remove the upper hook pin and take out the screw Note When installing a connector like the type shown below unscrew the lower hook pin also Then drive both accessory screws 8EXT ADVANCED HYBRID SYSTEM Screw 50 pin connector Hook pins Accessory screw Amphenol 57JE type Accessory screw 50 pi...

Page 69: ...enol 57JE type Plug to the connector drive the accessory screw into the upper part Fasten the accessory wire tie around the lower hook pin and the Amphenol 57JE type as shown Accessory screw Amphenol 57JE type Accessory wire tie 57JE type Hook pin Accessory wire tie ...

Page 70: ...stalled as follows Installing the DISA Card KX TA123291 1 Insert the upper side of the DISA Card into the two hooks on the main unit 2 Press down the two corners of the lower side of the DISA Card 3 Connect the cord to the DISA Card Connector Features Guide Reference Direct Inward System Access DISA DISA Card ...

Page 71: ...Cards 4 CO Line Expansion Unit can accept one Caller ID Card Installing to the Initial Outside Line Card 1 Loosen the eight screws to open the inside cover of the main unit Note If any cards units or cords are installed to the main unit remove them beforehand 2 Insert the Caller ID Card s to the connectors on the Outside Line Card Up to two cards can be installed to the initial Outside Line Card 3...

Page 72: ...D Card to the P board fitting the connectors 4 Put the P board back into the cabinet and fix the rear plate with the five screws Note For installing the 4 CO Line Expansion Unit to the main unit refer to 2 4 4 Installing Expansion Unit Programming Guide Reference 110 Caller ID Code Set 111 Caller ID Name Set 125 Area Code Assignment 126 Caller ID Modification for Local Call 127 Caller ID Modificat...

Page 73: ...e the doorphone into two halves 2 Install the base cover to the wall with two screws Note Two kinds of screws are included Please choose the appropriate one depending on your wall type 3 Connect the wires to the screws located in the front cover 4 Secure both halves together and re install the screw screw Panasonic Type 1 When the doorphone plate has been fixed to the wall When you wish to install...

Page 74: ...or modular connectors to the Doorphone Door Opener Interface Card Cabinet and pass the cords through the grooves in the cabinet 2 Attach the Doorphone Door Opener Interface Card Cabinet to the main unit and press down 3 Connect the cord to the Doorphone Door Opener Interface Card Connector To Terminal Box Installation ...

Page 75: ...of the terminal box 4 Connect the wires of doorphone 3 to the red and green screws of the terminal box 5 Connect the wires of doorphone 4 to the yellow and black screws of the terminal box 4 conductor wiring is required Doorphone 3 KX T30865 Doorphone 4 KX T30865 Yellow Red Black Green Terminal Box Panasonic Panasonic 4 conductor wiring is required Doorphone 1 KX T30865 Doorphone 2 KX T30865 Yello...

Page 76: ...General Installation 76 Installation Manual Connecting Door Openers 1 Loosen the screw to remove the cover 2 Loosen the screws on the terminal strip ...

Page 77: ...ugh the Holder Note Set the door opener paired with the doorphone For wiring UL 1015 AWG 22 twisted wire or the equivalent is recommended The wire should be between 1 2 mm and 2 4 mm 3 64 inch and 3 32 inch in diameter including the coating To door opener 3 To door opener 4 Holder To door opener 2 To door opener 1 D 1 2 mm 2 4 mm 3 64 inch 3 32 inch ...

Page 78: ...at connects to the main unit is shown below Programming Guide Reference 607 608 Doorphone Ringing Assignment Day Night Features Guide Reference Door Opener Doorphone Call 26 AWG Under 70 m 230 feet 24 AWG Under 113 m 370 feet 22 AWG Under 180 m 590 feet Doorphone KX T30865 Door Opener 22 AWG Under 180 m 590 feet A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic Panasonic ...

Page 79: ...iring to the modular jacks of 4 CO Line Expansion Unit and the amphenol connector of 8 Extension Expansion Unit 1 Note In the event of a power failure system memory is protected by a factory provided lithium battery There is no memory loss except the memories of Camp on Saved Number Redial Last Number Redial Call Park and Message Waiting The system changes the current connection to this connection...

Page 80: ...ont Cover 1 Fasten all the cables and cords with the cord fastener 2 Replace the cover and tighten the screw Note Be sure to tighten two screws or the unit may not work properly Panasonic D816 DIGITAL SUPER HYBRID SYSTEM screw screw A1232 ADVANCED HYBRID SYSTEM KX TA1232 Panasonic screw screw ...

Page 81: ...allation Manual 81 3 Tie together all of the connected cords and attach them to the wall so that the cords cannot be pulled out of the main unit Panasonic D816 DIGITAL SUPER HYBRID SYSTEM A1232 ADVANCED HYBRID SYSTEM KX TA1232 ...

Page 82: ... outlet 4 Turn the Power Switch on 5 Press the Reset Button with a pointed tool The power indicator will flash 6 Slide the System Clear Switch to the NORMAL position while the power indicator is flashing within approximately 10 seconds The system will be initialized with default values The system will also check the outside lines extensions and optional cards and units SYSTEM CLEAR CLEAR NORMAL RE...

Page 83: ...he system will not start up with the default values CAUTION The power supply cord is used as the main disconnect device ensure that the socket outlet is located installed near the equipment and is easily accessible Once you start up the system and you turn the power off do not perform the above procedure to start the system again Otherwise your programmed data will be cleared To start the system j...

Page 84: ...all Park is cleared Other data is not cleared by System Restart 1 Make sure that the System Clear Switch is set to the NORMAL position 2 Press the Reset Button with a pointed tool Notice After pressing the Reset Button if you notice that the System Clear Switch is set to the CLEAR position never slide the System Clear Switch to the NORMAL position within 20 seconds Otherwise all the system program...

Page 85: ...the default setting 1 Slide the System Clear Switch to the CLEAR position 2 Press the Reset Button with a pointed tool 3 Return the System Clear Switch to the NORMAL position while the power indicator is flashing within approximately 10 seconds Notice After pressing the Reset Button return the System Clear Switch to the NORMAL position in step 3 while the power indicator is flashing within approxi...

Page 86: ...General Installation 86 Installation Manual ...

Page 87: ...Troubleshooting Installation Manual 87 Section 3 Troubleshooting This section provides information for system and telephone troubleshooting ...

Page 88: ...itch of the telephone to the OUT or OFF position Bad extension Take the extension and plug it into another extension port that is working If the telephone does not work replace the phone Incorrect reset operation Press the Reset Button Noise in external paging Induced noise on the wire between the system and the amplifier Use a shielded cable as the connection wire between the system and amplifier...

Page 89: ...nection between the system and a single line telephone Connection between the system and a single line telephone that is polarity sensitive Continued on the following Use the correct cord inner 2 wires are for T R If a telephone equipped with an A A1 relay is connected to the system set the A A1 relay switch of the telephone to OFF KX TA1232 extension CAUSE SOLUTION Connection between the system a...

Page 90: ...ne No Outside lines are connected to the T2 T1 Connection between the central office and the system Continued from the previous Reconnect the outside lines to the T1 R1 or T2 R2 of the telephone jack using 2 conductor wiring Outside line KX TA1232 Outside line KX TA1232 CAUSE SOLUTION Outside lines are connected to the T2 R1 T2 R1 T1 R2 ...

Page 91: ...t does not ring The Ringer Volume Selector is set to OFF Set to HIGH or LOW During a power failure extensions connected to jack numbers 1 9 and 17 for KX TA1232 do not operate An analog proprietary telephone APT is connected to the jack The dialing mode tone or pulse is improper Disconnect the APT and connect a single line telephone Set the Tone Pulse switch to the other position Originating an ou...

Page 92: ...Button and setting the System Clear Switch to the NORMAL position while the Power Indicator is flashing Operation 1 If the system does not operate properly a Make sure that the System Clear Switch is set to the NORMAL position b Press the Reset Button with a pointed tool 2 If the system still does not operate properly a Set the System Clear Switch to the CLEAR position b Press the Reset Button wit...

Page 93: ... service person When the power supply stops certain extensions are automatically connected straight to specific outside lines Extension T R of jack number 1 Outside line 1 Extension T R of jack number 9 Outside line 3 Extension T R of jack number 17 Outside line 9 Connect single line telephones to the above extension jacks ...

Page 94: ...Troubleshooting 94 Installation Manual ...

Page 95: ...Index 95 Section 4 Index ...

Page 96: ...rce Connection 48 External Pager Paging Equipment Connection 47 F Frame Ground Connection 35 G General Description 23 I Installing Expansion Unit 62 K KX T30865 Doorphone 22 L Lightning Protectors 54 Location of Interfaces 31 Location of Optional Cards and Units 57 M Maximum Cabling Distance 38 Module Expansion 16 O Opening Front Cover 34 Options 22 Outside Line Connection 37 P Paralleled Telephon...

Page 97: ...Index 97 W Wall Mounting 32 ...

Page 98: ...Index 98 ...

Page 99: ...Index 99 ...

Page 100: ...Puerto Rico Inc Ave 65 de Infantería Km 9 5 San Gabriel Industrial Park Carolina Puerto Rico 00985 Printed in the United Kingdom This manual is copyrighted by Kyushu Matsushita Electric Co Ltd KME Under the applicable copyright laws this manual may not be reproduced in any form in whole or part without the prior written consent of KME and its licensee 2001 Kyushu Matsushita Electric Co Ltd All Rig...