9.2 Extension [2]
152
Programming Manual
Value Range
01–24
Extension
Indicates the extension number and name (reference only).
Value Range
Extension no. and name specified in
Ext. no.
and
Name
on the
9.1.3 Numbering Plan [1-3]
screen
Programming Manual References
9.1.3 Numbering Plan [1-3]—Ext. no., Name
MW for Another Extension
Specifies whether an extension can use the Message Waiting for Another Extension feature. If this program
is disabled (unchecked), an extension user cannot use a button as a Message for another extension button.
Default
All jacks: On
Value Range
On (checked), Off (unchecked)
Programming Manual References
[618] Message Waiting for Another Extension
Feature Manual References
1.1.83 Message Waiting for Another Extension
SLT MW
Enables the PBX to send dial tone 3 as a message waiting notification to an SLT.
Default
All jacks: Off
Value Range
On (checked), Off (unchecked)
Programming Manual References
[619] SLT Message Waiting
Feature Manual References
1.1.82 Message Waiting