2.2 PT Programming—Procedures
Programming Manual
33
[206] Dialing Start Time
Selects the minimum length of time that the PBX waits after seizing an outside (CO) line before dialing.
Feature Manual References
1.1.71 Line Access, Outside (CO) Line—SUMMARY
[208] Inter-digit Time
Selects the length of time allowed between digits for an outgoing outside (CO) line call.
Programming Manual References
[211] No Dial Disconnection
Feature Manual References
1.1.117 Toll Restriction (TRS)
[211] No Dial Disconnection
Selects whether or not to disconnect an outside (CO) line when an extension user does not dial anything
within 10 seconds after seizing the outside (CO) line.
Programming Manual References
[208] Inter-digit Time
Feature Manual References
1.1.117 Toll Restriction (TRS)
[214] BV Recording Time
Selects the maximum recording time for each voice message.
Feature Manual References
1.1.8 Built-in Voice Message (BV)
2
0
6
NEXT
SELECT
STORE
END
( 0/250/500/750/
1000/1250/1500 ms)
2
0
8
NEXT
SELECT
STORE
END
(5/ 10/15/20 s)
2
1
1
NEXT
SELECT
STORE
END
(Enable/ Disable)
2
1
4
NEXT
time
STORE
END
(1…20 min)
5 min
Summary of Contents for KX-TA82483 - Expansion Cards
Page 10: ...10 Programming Manual ...
Page 80: ...2 2 PT Programming Procedures 80 Programming Manual ...
Page 86: ...3 6 Standard Buttons 86 Programming Manual ...
Page 90: ...4 1 Software Modes 90 Programming Manual ...
Page 106: ...6 4 Profile Editor 106 Programming Manual ...
Page 110: ...7 4 System Data Setting Menu 110 Programming Manual ...
Page 229: ...Programming Manual 229 Index ...
Page 233: ...Index Programming Manual 233 ...