2.8 [2] System
PC Programming Manual
121
Programming Manual References
None
Feature Manual References
1.13.4 Pause Insertion
System Wireless—PS Out of Range Timer
When the destination of an incoming call is a PS, specifies the length of time the PBX searches for
the PS before setting its status to Out of Range.
If "0" is assigned, the timer is controlled by the cell station.
Default
0 s
Value Range
0 s, 4 s, 8 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
None
SVM—Recording Time
Specifies the maximum length of a message recorded by the SVM feature.
Default
120 s
Value Range
1–600 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
2.10.7 [4-1-6] Wired Extension—Simplified Voice Message
2.10.12 [4-2-4] Portable Station—Simplified Voice Message
Feature Manual References
1.16.5 SVM (Simplified Voice Message)