2.8 [2] System
144
PC Programming Manual
Feature Manual References
1.20.2 Walking Extension
Data Line Security Set / Cancel
Specifies the feature number used to set or cancel Data Line Security (i.e., preventing signals from
other extensions during data transmission).
Default
*730
Value Range
Max. 4 digits (consisting of 0–9, *, and #)
Maintenance Console Location
2.8.8 [2-6-1] Numbering Plan—Main
Programming Manual References
None
Feature Manual References
1.4.1 Data Line Security
Call Waiting Mode: Manual Call Waiting for Extension Call
Specifies the feature number used to set or change the method of receiving a Call Waiting notification
from an extension.
Default
*731
Value Range
Max. 4 digits (consisting of 0–9, *, and #)
Maintenance Console Location
2.8.8 [2-6-1] Numbering Plan—Main
Programming Manual References
None
Feature Manual References
1.3.9 Call Waiting Tone
Call Waiting Mode: Automatic Call Waiting
Specifies the feature number used to set or cancel a Call Waiting notification from a CO line,
doorphone, or a call via an incoming call distribution group.