2.16 [10] Maintenance
438
PC Programming Manual
Default
CR+LF
Value Range
CR+LF, CR
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.16.1 SMDR (Station Message Detail Recording)
Communication—Parity Bit
Selects a parity bit code that indicates what type of parity is used to detect an error in the string of
bits composing a character.
Make an appropriate selection depending on the requirements of the printer or personal computer.
Default
None
Value Range
None, Mark, Space, Even, Odd
Maintenance Console Location
2.16.1 [10-1] Main
Programming Manual References
None
Feature Manual References
1.16.1 SMDR (Station Message Detail Recording)
Communication—Word Length
Specifies the number of bits in each byte of a character.
When connecting the KX-TAW848 Maintenance Console to the PBX using an RS-232C cable, assign
the following values to the Serial Interface (RS-232C) port of the PBX:
Word Length
: 8 bit,
Parity Bit
: None,
Stop Bit
: 1 bit
CAUTION
Do not use the following combinations:
•
Word Length
: 8 bit,
Parity Bit
: Space,
Stop Bit
: 1 bit
•
Word Length
: 8 bit,
Parity Bit
: Mark,
Stop Bit
: 2 bit
•
Word Length
: 8 bit,
Parity Bit
: Space,
Stop Bit
: 2 bit