2.7 [1] Configuration
PC Programming Manual
85
•
Select the desired cell in the column, and then click
Command
.
Default
Current status
Value Range
INS: The port is in service.
OUS: The port is out of service.
Maintenance Console Location
2.7.8 [1-1] Slot—LCO Port
Programming Manual References
2.7.9 [1-1] Slot—LCO Port—Port Command
Feature Manual References
None
Dialing Mode
Selects the type of signal used to dial out to the analog CO line.
Default
DTMF
Value Range
DTMF, Pulse
Maintenance Console Location
2.7.8 [1-1] Slot—LCO Port
Programming Manual References
None
Feature Manual References
1.4.2 Dial Mode Selection
CPC Signal Detection Time—Outgoing, Incoming
Specifies the length of time required by the PBX to detect a CPC signal on outgoing or incoming CO
line calls before disconnecting the line. When
None
is selected here, the line will not be disconnected
when a CPC signal is not detected.
Default
400 ms
Value Range
None, 6.5 ms, 8 × n (n=1–112) ms