Items
Adjustment
Point
Procedure*
Check
(I)*
Transmitted
Power
Confirmation
TP15
Remove the Antenna before starting step from 1 to 5.
1. Configure the DECT tester(CMD60) as follows;
<Setting>
-Testmode: PP
-RFPI: 0102030405
-Traffic Channel: 5
-Traffic Slot: 4
-Mode: Loopback
2. Execute the command "testmode".
3. Execute the command "regcmd60"
4. Initiate connection from DECT tester.
5. Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
(J)
Modulatoin
Check and
Adjusment
TP15
Follow steps 1 to 4 of (I) above.
1. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/div using data type Fig31.
2. Adjust the B-Field Modulation if required. (Execute the command "Readmod" and
"Writemod xx", where xx is the value.)
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
(K) Frequency Offset
Confirmation
-
Follow steps 1 to 4 of (I) above.
1. Confirm that the frequency offset is < ± 40kHz.
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
42
Summary of Contents for KX-TCD400GC
Page 46: ...18 FREQUENCY TABLE MHz 46 ...
Page 52: ...24 CPU DATA BASE UNIT 24 1 IC2 BBIC 52 ...
Page 56: ...45 MICP A I 56 ...
Page 60: ...60 ...
Page 61: ...28 CABINET AND ELECTRICAL PARTS LOCATION HANDSET 29 ACCESSORIES AND PACKING MATERIALS 61 ...
Page 62: ...30 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 30 1 Base Unit 30 2 Handset 62 ...
Page 91: ...4 1 5 8 PbF 1 28 18 IC3 IC2 IC1 11 64 1 16 17 32 49 48 33 Marked ...
Page 93: ...Marked PbF IC1 IC2 100 80 5 8 4 1 50 51 30 31 1 11 18 1 28 IC3 ...