General Programming
80
Programming Guide
[114]
VM Command DTMF Set
Description
Sets the DTMF (Dual Tone Multi-Frequency) command signals transmitted to your Voice
Processing System (VPS). There are four commands available: Leave Message; Get Message;
Automated Attendant Service; Voice Mail Service. These commands are used in the following
ways:
(A) If your VPS is used for Voice Mail (VM) Service
(1) Call Forwarding / Intercept Routing to Voice Mail
If a call is forwarded to the VPS, your system will send a mailbox number to the VM port. This
allows the caller to leave a message without knowing the mailbox number.
•
Required entries (selections):
LV-MSG
(Leave Message): This command is transmitted to a VM port if a call is
forwarded or intercepted and rerouted to the port.
AA-SVC
(Automated Attendant Service): If AA Service is set to "Start" in program
[990], Area 01 - Bit 16, the "AA-SVC" command is sent to a VM port if an incoming
outside call is answered by the VM port.
•
Other programming required (program addresses): [106]; [602]; [609]; [990], Area 01 -
Bit 16; [990], Area 02 - Bit 8
(2) Hearing the message at the extension
If the VPS receives a message and lights the MESSAGE button indicator of the dialed
telephone, the telephone user can hear the message by pressing the MESSAGE button.
•
Required entries (selections):
GETMSG
(Get Message): This command is transmitted to a VM port when the message
receiver presses the MESSAGE button.
VM-SVC
(Voice Mail Service): The "VM-SVC" command is a code transmitted
preceding the "GETMSG" command above.
This is effective to switch to VM port when an AA port lights the MESSAGE indicator.
•
Other programming required (program addresses): [609]; [990], Area 02 - Bit 8
(B) If your VPS is used for Automated Attendant (AA) Service
An AA port answers an incoming outside call to provide AA services, such as call
transfer, receiving a message.
•
Required entries (selections):
VM-SVC
(Voice Mail Service): The "VM-SVC" command is a code transmitted before
the "LV-MSG" code if an operator transfers a call to an extension and then it is
forwarded to an AA port so that the AA port can be switched to the VM port temporarily.
•
Other programming required (program addresses): [106], [602]
Selection
•
LV-MSG
/
GETMSG
/
AA-SVC
/
VM-SVC
•
DTMF signal number:
16 digits (max.)
Default
LV-MSG — H; GETMSG — *H; AA-SVC — #8 ; VM-SVC — #6
Summary of Contents for KX-TD1232
Page 8: ...Table of Contents 8 Programming Guide...
Page 26: ...General Programming Instructions 26 Programming Guide...
Page 27: ...General Programming Programming Guide 27 Section 2 General Programming...
Page 59: ...General Programming Programming Guide 59 Features Guide References Flexible Numbering...
Page 76: ...General Programming 76 Programming Guide Features Guide References Caller ID...
Page 100: ...General Programming 100 Programming Guide Call Log Incoming...
Page 109: ...General Programming Programming Guide 109 Features Guide References Message Waiting...
Page 167: ...General Programming Programming Guide 167 Features Guide References T1 Line TIE Line Service...
Page 177: ...General Programming Programming Guide 177 Features Guide References Dial Type Selection...
Page 181: ...General Programming Programming Guide 181 Features Guide References Caller ID...
Page 193: ...General Programming Programming Guide 193 Features Guide References Flash...
Page 208: ...General Programming 208 Programming Guide Features Guide References None...
Page 212: ...General Programming 212 Programming Guide Features Guide References None...
Page 216: ...General Programming 216 Programming Guide Features Guide References None...
Page 218: ...General Programming 218 Programming Guide Features Guide References None...
Page 225: ...General Programming Programming Guide 225 TIE Line Service...
Page 227: ...General Programming Programming Guide 227 T1 Line TIE Line Service...
Page 267: ...General Programming Programming Guide 267 Features Guide References None...
Page 303: ...General Programming Programming Guide 303 T1 Line...
Page 320: ...General Programming 320 Programming Guide TIE Line Service...
Page 324: ...General Programming 324 Programming Guide T1 Line TIE Line Service...
Page 326: ...General Programming 326 Programming Guide TIE Line Service...
Page 331: ...General Programming Programming Guide 331 T1 Line...
Page 377: ...Default Values Programming Guide 377 Section 3 Default Values...
Page 389: ...Index 389 Section 4 Index...
Page 393: ...Index 393...
Page 394: ...Index 394...
Page 395: ...Index 395...