4.6
Outside Line Programming
Flash Time
413
4-106
System Programming
Description
Assigns the length of the flash time. If your system is installed
behind a host PBX or Centrex line, External Feature Access (EFA)
is necessary to obtain their services. To enable it, select a required
hooking signal sending time for the outside line.
Selection
• Outside line (CO) number: 1 through 3,
(
=all outside lines)
• Time (milliseconds): Disable (no EFA) / 80 / 96 / 112 / 200 / 300 /
400 / 500 / 600 / 700 / 800 / 900 / 1000 /
1100 / 1200
Default
All outside lines – 600 ms
Programming
1.
Enter 413.
Display: 413 FLASH TIME
2.
Press NEXT.
Display: CO Line NO?
→
3.
Enter an outside line number.
To enter outside line number 1, you can also press NEXT.
Display example: CO1: 600msec
4.
Keep pressing SELECT until the desired time is displayed.
5.
Press STORE.
6.
To program another outside line, press NEXT or PREV, or
SELECT and the desired outside line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• You may disable EFA, if not required. The Flash feature will be in
effect in place of EFA. Program [414] “Disconnect Time” is used to
select the time required for the Flash feature.
• The flash time required is determined by the central office or the host
PBX lines.
• To assign all outside lines to one selection, press the
key in step 3.
In this case, the display shows the contents programmed for outside line
1.
Feature References
Section 3, Features
External Feature Access