10.4
SMDR
254
Maintenance
Parameter
[Format] Skip Perforation
Default
0
Value Range
0-95 lines
Description/Function
Determines the number of lines to be skipped at the end of every
page.
The number of lines to skip is simply the number specified in this
parameter.
The number of lines printed is the difference between the Page
Length number and the Skip Perforation number.
Reference
None
Parameter
[Duration Log] Outgoing Calls
Default
All
Value Range
1.
None
2.
All
3.
Toll Only
Description/Function
Specifies the type of outgoing calls which will be printed out by
SMDR.
1.
None : No printout
2.
All : All calls
3.
Toll Only : Toll calls only
Reference
None
Parameter
[Duration Log] Incoming Calls
Default
On
Value Range
1.
On
2.
Off
Description/Function
Specifies whether or not incoming calls will be printed out by
SMDR.
1.
On: All calls
2.
Off: No printout
Reference
None
Summary of Contents for KX-TD500CE
Page 5: ...Configuration 5 Section 1 Configuration...
Page 30: ...1 9 PRI Port Assignment 30 Configuration...
Page 31: ...System 31 Section 2 System...
Page 32: ...2 1 System 32 System 2 1 System Used to assign parameters which affect system wide operation...
Page 100: ...2 9 Language Data 100 System...
Page 101: ...Group 101 Section 3 Group...
Page 102: ...3 1 Group 102 Group 3 1 Group Used to assign various group parameters...
Page 131: ...Line 131 Section 4 Line...
Page 183: ...Features 183 Section 5 Features...
Page 184: ...5 1 Features 184 Features 5 1 Features Used to assign parameters for various system features...
Page 218: ...5 15 Hotel 218 Features...
Page 219: ...Toll Restriction 219 Section 6 Toll Restriction...
Page 225: ...ARS Automatic Route Selection 225 Section 7 ARS Automatic Route Selection...
Page 234: ...7 5 Digits Modification Table 234 ARS Automatic Route Selection...
Page 235: ...Private Network 235 Section 8 Private Network...
Page 239: ...DDI DID 239 Section 9 DDI DID...
Page 246: ...9 2 Number Transformation 246 DDI DID...
Page 247: ...Maintenance 247 Section 10 Maintenance...
Page 268: ...10 7 System Time 268 Maintenance...
Page 269: ...Programming Error Messages 269 Section 11 Programming Error Messages...
Page 284: ...11 3 Information Message IXXXX 284 Programming Error Messages...
Page 285: ...Default Values 285 Section 12 Default Values...
Page 313: ...Default Values 313...