2.4
Class of Service (COS)
System
63
Parameter
SDN COS
Default
Own Extension
Value Range
1.
Own Extension
2.
PDN
Description/Function
This setting is applied when an extension user makes an outside call
using an SDN button on his or her own extension.
1.
Own Extension
COS (TRS level) of his / her own applies when making an
outside call using the SDN button.
2.
PDN
COS (TRS level) of the owner extension applies when making
an outside call using the SDN button.
(Assignable for a DN type PT user only.)
Reference
• 4.1.2 Customising the Buttons (U/M)
Parameter
Off-Hook Call Announcement (OHCA)
Default
Enable
Value Range
1.
Enable
2.
Disable
Description/Function
Specifies whether to utilise OHCA / Whisper OHCA feature or not.
Note
•
This setting is valid at the following PT extensions:
KX-T7130, KX-T7235, KX-T7536.
Reference
• 1.6 Originating Features (F/G)
– Off-Hook Call Announcement (OHCA)
– Off-Hook Call Announcement (OHCA), Whisper
• 2.7.3 Receiving a Call Waiting (Call Waiting / Off-Hook Call
Announcement [OHCA] / Whisper OHCA) (U/M)
Summary of Contents for KX-TD500CE
Page 5: ...Configuration 5 Section 1 Configuration...
Page 30: ...1 9 PRI Port Assignment 30 Configuration...
Page 31: ...System 31 Section 2 System...
Page 32: ...2 1 System 32 System 2 1 System Used to assign parameters which affect system wide operation...
Page 100: ...2 9 Language Data 100 System...
Page 101: ...Group 101 Section 3 Group...
Page 102: ...3 1 Group 102 Group 3 1 Group Used to assign various group parameters...
Page 131: ...Line 131 Section 4 Line...
Page 183: ...Features 183 Section 5 Features...
Page 184: ...5 1 Features 184 Features 5 1 Features Used to assign parameters for various system features...
Page 218: ...5 15 Hotel 218 Features...
Page 219: ...Toll Restriction 219 Section 6 Toll Restriction...
Page 225: ...ARS Automatic Route Selection 225 Section 7 ARS Automatic Route Selection...
Page 234: ...7 5 Digits Modification Table 234 ARS Automatic Route Selection...
Page 235: ...Private Network 235 Section 8 Private Network...
Page 239: ...DDI DID 239 Section 9 DDI DID...
Page 246: ...9 2 Number Transformation 246 DDI DID...
Page 247: ...Maintenance 247 Section 10 Maintenance...
Page 268: ...10 7 System Time 268 Maintenance...
Page 269: ...Programming Error Messages 269 Section 11 Programming Error Messages...
Page 284: ...11 3 Information Message IXXXX 284 Programming Error Messages...
Page 285: ...Default Values 285 Section 12 Default Values...
Page 313: ...Default Values 313...