4.6
CO Line Programming
Register Recall Signal Time
System Programming
4-93
413
Description
Assigns the length of the register recall signal time. If your system
is installed behind a host PBX, External Feature Access (EFA) is
necessary to obtain its services. To enable it, select a required
register recall signal sending time for the CO line group.
Selection
• CO line group (TRG) number: 1 through 8,
(
=all CO line groups)
• Time (milliseconds): Disable (no EFA) / 80 / 96 / 112 / 200 / 300 /
400 / 500 / 600 / 700 / 800 / 900 / 1000 /
1100 / 1200
Default
All CO line groups – 96 ms
Programming
1.
Enter 413.
Display: Register Recall
2.
Press NEXT.
Display: TRK GRP NO?–>
3.
Enter a CO line group number.
To enter CO line group number 1, you can also press NEXT.
Display example: TRG1: 600msec
4.
Keep pressing SELECT until the desired time is displayed.
5.
Press STORE.
6.
To program another CO line group, press NEXT or PREV, or
SELECT and the desired CO line group number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• You may disable EFA, if not required. The Recall feature will be in
effect in place of EFA. Program [414] “Disconnect Time” is used to
select the time required for the Recall feature.
• The register recall signal time required is determined by the central
office or the host PBX lines.
• To assign all CO line groups to one selection, press the
key at step 3.
In this case, the display shows the contents programmed for CO line
group 1.
• Program [401] “CO Line Group Assignment” is used to assign each CO
line to a CO line group.
Feature References
Section 3, Features,
External Feature Access
Recall