Installation
2-59
2.8
System Data Clear
After storing or changing the system programming data, you can
clear the programming data stored in the system. The system will
restart with the default settings.
1. Slide the system clear switch to “CLEAR.”
2. Press the Reset button with a pointed tool.
3. Return the system clear switch to “NORMAL” while the power
indicator is flashing (approximately within 10 seconds).
Notice
After pressing the Reset button, return the system clear switch to
“NORMAL” at step 3 while the power indicator is flashing
(approximately within 10 seconds). Otherwise, the system is not
cleared.