5.2. SYSTEM CAPACITY
5.2.1. Power Supply Unit Selection
Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of "load figures"
from the type and number of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type
Load Figure
PT
DPT (T76xx series and T7560, T7565)
1
Other DPT/APT/DSS Console
4
Extension Card *1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS
4
ISDN Extension
2
Voice Mail
1
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
PSU Type
Maximum Load Figures
Available
PSU-S (KX-TDA0108XJ/X)
64
Available for the KX-TDA100
PSU-M (KX-TDA0104XJ/X)
128
Available for the KX-TDA100, KX-TDA200 and KX-TDA600
PSU-L (KX-TDA0103XJ/X)
512
Available for the KX-TDA200 and KX-TDA600