Connection Examples for KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/
KX-TDE200/KX-TDE600
Refer to the following examples to connect a CS to the PBX.
KX-TDA0152/KX-TDA0142 connecting to KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/
KX-TDE200/KX-TDE600
Note
The illustration of the PBX is based on the KX-TDE200.
CSIF8 Card
1
2
3
4
D1
POWH
POWL
D2
D1
POWH
POWL
D2
1
2
3
4
5
6
7
8
Port 1
Maximum Distance
444 m (1457 ft)
694 m (2277 ft)
1000 m (3281 ft)
694 m (2277 ft)
Cable
26 AWG:
24 AWG:
22 AWG:
CAT 5:
CS (RJ11)
Pin No.
Signal Name
CSIF card (RJ45)
Pin No.
Signal Name
Accessories and User-supplied Items for the CS
Accessories (included):
Screws
´
2, Washers
´
2
User-supplied (not included):
RJ11 connector
Note
For details about the CSIF card, refer to the Installation Manual for your PBX.
Document Version 2009-12
Quick Installation Guide
25
7 Connecting a Cell Station to the PBX