Model No.   

KX-TDA0480

4-Channel VoIP Gateway Card

Installation Manual

Thank you for purchasing the Panasonic 4-Channel VoIP Gateway Card, KX-TDA0480.
Please read this manual carefully before using this product and save this manual for future use.

Summary of Contents for KX-TDA0480

Page 1: ...4 Channel VoIP Gateway Card Installation Manual Thank you for purchasing the Panasonic 4 Channel VoIP Gateway Card KX TDA0480 Please read this manual carefully before using this product and save this manual for future use ...

Page 2: ... Planning of this document In addition to this introduction this document is organised into the following sections KX TDA0480 Overview Planning Physical Installation Logical Installation At the end of this document are appendices that provide detailed information on topics that will be useful during the planning and installation process Appendix sections deal with advanced topics related to instal...

Page 3: ...Up the KX TDA0480 and Verify Operation 48 4 Logical Installation 4 1 Logical Installation Methods 50 4 2 Maintenance Console Software Overview 51 4 3 Install Maintenance Console Software 52 4 4 Start Maintenance Console Software and Login 53 4 5 MCS Main Directory Window 54 4 6 Create a New Group 56 4 7 Create New Units 59 4 7 1 RS232C Port Configuration 60 4 7 2 Create a New Gateway KX TDA0480 Un...

Page 4: ...NS Functions 142 A3 2 KX TDA0480 Internal DNS Database 142 A4 Pad Control and AGC 146 A4 1 PAD Controls 146 A4 2 AGC 146 A5 Optimising Performance 147 A5 1 Voice Volume 147 A5 2 Transmission Delays 147 A5 3 Firewalls 151 A6 Configuration Files 153 A7 FTP File Transfers 155 A8 Worksheet Masters 160 Glossary 165 ...

Page 5: ...KX TDA0480 Overview Installation Manual 5 Section 1 KX TDA0480 Overview ...

Page 6: ...mpresses and packages the signal for transmission over digital TCP IP networks On the incoming side the KX TDA0480 reverses this process receiving voice or fax data packets and translating them back into appropriate voice and fax signals Simplified IP Gateway network connection In summary the KX TDA0480 provides organisations with a reliable solution for high quality integrated voice and fax commu...

Page 7: ...roprietary dynamic jitter buffer and Dynamic Echo Cancellation further assure uninterrupted and natural speech communications Network Connectivity The KX TDA0480 supports a 10BaseT Ethernet interface for network connection WAN connectivity is provided through any IP router H 323 Compliance The KX TDA0480 is H 323 Version 2 compliant When implemented within an H 323 network units are simultaneously...

Page 8: ...time installation the Maintenance Console Software is used in conjunction with a common RS232C interface in order to establish a unit s new IP addressing Once this is done and units are on line in the network the Maintenance Console Software can be used to configure and troubleshoot units remotely Alternatively the KX TDA0480 configuration files can be manually configured and uploaded to units or ...

Page 9: ...ing data and telephony networks Proper planning will make the installation process go more easily and will assure that the network can be easily maintained and upgraded This section covers the following planning related topics 1 General discussion of the KX TDA0480 configurations and components 2 Presentation and description of worksheets used to record information needed to install and configure ...

Page 10: ...A0480 installation The KX TDA0480 must be connected to the LAN using an Ethernet interface and must be connected to the WAN e g IP network using a router Only one IP network Internet Intranet and VPN can be used to interconnect communicating devices The KX TDA0480 requires that the network used support static IP addressing Basic network configuration Static addressing means that the IP addresses a...

Page 11: ...igure Examples of undesirable network configurations are not allowable These configurations will produce large voice delays voice quality deterioration and unreliable connections Examples of undesirable network configurations IP Network IP Network 1 Telephone Network IP Network 2 ...

Page 12: ... above illustrates many of the KX TDA0480 s capabilities it represents only one of many possible network configurations The various features and methods for implementing KX TDA0480 products are discussed in greater detail in the following sections of this guide Whatever the configuration envisioned when planning a network installation take care to avoid configurations that introduce unnecessary de...

Page 13: ...Networks LANs and Wide Area Networks WANs and for end point terminal devices which interact across the networks When implemented within an H 323 network the KX TDA0480 compliance helps to insure that The KX TDA0480 is interoperable with other H 323 compliant devices irrespective of manufacturer Communications between various networks LAN and WAN and between end point devices terminals is as seamle...

Page 14: ... PSTN networks When the KX TDA0480 is installed in an H 323 network the unit is in continuous communication with the H 323 Gatekeeper and uses the call addressing and management services provided by the Gatekeeper In addition the KX TDA0480 provides the interface between the worlds of voice and data communications performing for example voice compression decompression and voice and fax data packet...

Page 15: ... files must be updated DNS configuration files should only be uploaded to units AFTER all network units have been setup in the MCS 2 1 3 G3 Fax The KX TDA0480 is capable of transmitting faxes using the data network to which the unit is connected and will automatically differentiate between fax and voice transmissions Fax communication over a data network uses error checking flow control protocols ...

Page 16: ... TDA0480 sends from among Auto Alphanumeric and Signal Operational limits When a unit is configured to use DTMF regeneration the feature may introduce some transmission delay In most cases Voice Mail IVR Auto Attendant it will be the calling party which will need to send DTMF tones by dialling numbers As a general rule it is best to avoid duplicating detection on two communicating KX TDA0480 This ...

Page 17: ...Manual 17 In the case of the third unit with no DTMF regeneration enabled duplication is also avoided since units with DTMF regeneration detects the absence of the feature on the unit and transmits DTMF using the voice path ...

Page 18: ...ds and telephone numbering systems Data from the Sample Network Diagram illustrated in Appendix A1 of this document are included Where applicable field defaults and applied values are indicated in the text by an underscore Sample network IP addressing and telephone numbering examples are illustrated in Appendices A1 and A2 Reproduction masters for the worksheets can be found in Appendix A8 2 2 1 N...

Page 19: ...me field allows for entry of an unrestricted alphanumeric string For convenience the Group Names in the sample worksheet are designated as the names of the cities in which the units will be installed This worksheet contains all of the information needed to initialise a network s KX TDA0480 using the Maintenance Console Software Unit Setup Wizard If this setup information is uploaded to each unit a...

Page 20: ...ly supplied by a network administrator Route IP Address 1 GW_IP 1 Use the Route IP Address 1 field to record the IP address of the primary gateway to be associated with each of the network units For each unit the unit s Gateway 1 i e primary Gateway is the one that will be accessed by the unit during normal operation The KX TDA0480 s gateway is typically a router or similar device This address mus...

Page 21: ...the DNS Connection Information Worksheet to record summary information needed to configure these facilities The IP address and Destination Office Code information on this worksheet is also used to configure Gatekeeper Inter equipment Routing TRS DAT information A complete discussion of IP Gateway network DNS configuration is provided in Appendix A3 of this document See section 4 9 1 Configure Gate...

Page 22: ...d IP Address Use the Unit Name and IP Address field to record the unit name and IP address for each connection to be defined This information can be transferred from the Network Units List Worksheet Connection port no Specification of TCP port number for call control incoming calls Default 1720 Terminal Code Use the Terminal Code field to record the Terminal Codes for the immediate KX TDA0480 PBX ...

Page 23: ...e number of digits used for the extension number For the sample NY01 most of the destinations have remaining digits set to 2 The one exception is the PSTN destination in which case the remaining digits is 10 allowing PSTN numbers up to 10 digits in length to be accessed e g 805 555 1212 Setting remaining digits to 10 does not mean that the user must dial all 10 digits when calling a number Comment...

Page 24: ...on Layer utility that provides a mechanism to manage and control network equipment from a central console system The KX TDA0480 report any error codes or fault codes to the central console Network Management System NMS by sending out Traps Trap IP 1 SNMP_TRPDST Record the IP address for the first Trap Transmission facility The IP address must conform to Internet Protocol addressing requirements e ...

Page 25: ...ional secondary Gatekeeper WARNING To configure other Gatekeeper devices refer to the manufacturer s documentation A Gatekeeper provides the telephone number to IP Address translation plus additional services depending on the feature set of the Gatekeeper used When an H 323 IP Gateway network is implemented a Gatekeeper device must be configured as part of the network Provisions are also made for ...

Page 26: ...eset and Fan Fault If the parameters for Notify E mail are not configured the feature is disabled Primary SMTP Server Record the IP address of the primary SMTP server The IP address must conform to Internet Protocol addressing requirements e g nnn nnn nnn nnn where nnn a value of 0 to 255 excluding 0 0 0 0 and 255 255 255 255 There is no default value for this field Secondary SMTP Server If a seco...

Page 27: ...diagrams in Appendices A1 Voice Over IP Addressing and A2 Numbering Systems Once this worksheet is completed the information is used to logically configure a unit The logical parameters are configured using the Maintenance Console Software Once this information is entered into the software the configuration file is uploaded to the unit and is recorded in unit s internal OFDD VHO file The Maintenan...

Page 28: ...tern No 1 or 2 For additional items use extension from BR A Priority 1 Trunk Group No Priority 2 Trunk Group No 1 Port 1 Port 2 Protocol H 323 Qual Effic Payload 80byte Qual Effic Bandwidth 12 0K bps Primary CODEC G 729a Secondary CODEC G 723 1 Regular Timing 0 Disconnect on Errors 10 Error Detect Timing 3 Reconnect on Errors 1 Signalling Port 1720 RTP Start Port 5004 H 245 Start Port 1721 Connect...

Page 29: ...ame to be associated with a unit Gateway in the Maintenance Console Software The Maintenance Console Software requires this information before a unit can be defined and configured using the Maintenance Console Software The Unit Name field allows entry of an unrestricted alphanumeric string In the sample worksheet the Unit Name is NY01 General Use the General section of the worksheet to record unit...

Page 30: ...value of 0 to 255 excluding 0 0 0 0 and 255 255 255 255 This address usually applies to a router or similar device to which the unit is connected IP addressing information is usually supplied by a network administrator There is no default value for this field In the sample worksheet the Gateway 1 IP address is recorded as 133 149 1 1 Gateway 2 IP GW_IP Use the Gateway address field to record the a...

Page 31: ...er password is entered as mainte e g the default password Tone This parameter is irrelevant to the setting of the KX TDA0480 Numbering This parameter is irrelevant to the setting of the KX TDA0480 Trunk Data Use the Trunk Data section of the worksheet to record information needed to configure each of the active ports on the KX TDA0480 Port No ITRK The Port field indicates the port to be configured...

Page 32: ...n the sample the Trunk Group parameter for all ports is recorded as the default 1 e g All ports are members of the same Trunk Group Delete Digits TGNINFO Use the Delete Digits field to record the number of digits to be deleted from the received number In the sample the Delete Digits parameter for all ports is configured to the default value of 0 Length of Call Reference ITRK This parameter must al...

Page 33: ...s for the KX TDA0480 In 0dB and Out 0dB In a few cases these settings may need to be adjusted See Appendix A4 Pad Control and AGC for details Adjustments of the nature must be performed on a case by case basis DTMF Detect DTMF The KX TDA0480 capable of using of DTMF When DTMF is enabled the unit passes digits after a call has been established the KX TDA0480 on the originating end detects the DTMF ...

Page 34: ...ed through the PBX main unit The Hunt Pattern defines which Trunk Group will be accessed when a call is processed and how the call will be routed through the PBX main unit Destination numbers always consist of one or more PBX Codes Each Trunk Group defined in the Trunk Data folder can be associated with a PBX Code When there are two or more Trunk Groups defined for a single KX TDA0480 grouped port...

Page 35: ...en calling through the KX TDA0480 8 digits maximum Every Hunt Pattern must be associated with a PBX Code Hunt Pattern No HNTPTN Use the Hunt Pattern No field to record the number of the pattern to be associated with the Destination Number Each Destination number will have a Hunt Pattern number associated with it i e 1 or 2 Trunk Priority Use the Trunk Priority section of the Worksheet to define th...

Page 36: ...ort on the KX TDA0480 Provide information for each of the unit s active ports Protocol RTP_HEAD Use the Protocol field to record the voice protocol to be used by the port Two options are possible In the sample the Protocol for all ports is recorded as the default value H 323 Codec Information AUDIO_CAP The principle difference between Codecs is their compression capabilities and their performance ...

Page 37: ...ted The default values are shown in the following table The bytes and bandwidth values are inversely related in a predetermined ratio In the Maintenance Console Software the values are adjusted using a slide bar control that maintains the correct ratio In the sample Efficiency is recorded as the default value 80 bytes 12 0 Kbps Network Use the Network section of the worksheet to record parameters ...

Page 38: ...ing checking if Disconnect on Errors times bad packets are detected then link failure is declared Regular Timing checking is halted and Error Detect checking is started Disconnect on Errors should be in the range of 1 to 100 The default setting for this value is 10 times Reconnect on Errors UPLINK During Error Detect checking if Reconnect on Errors times good packets are detected then normal link ...

Page 39: ... 5008 and 5010 Odd ports are RTCP e g 5005 5007 5009 and 5011 Connect Time NOCTIME Use the Connect Time field to record the time allowed for a connection to be established This parameter defines the time frame during which the KX TDA0480 will try to establish the call If a call is not established within this time e g the called KX TDA0480 is not responding a fast Busy Tone is returned When impleme...

Page 40: ...rovide the best results Start Recovery RX_BUFFER Record in units of ms the delay time threshold value for the start of recovery delay processing 1 In most cases the default value 200 ms will provide the best results End Recovery RX_BUFFER Record in units of ms the delay time threshold value for stopping the recovery delay processing which started at the time specified as Start Recovery data In mos...

Page 41: ...tallation process it is recommended that all planning worksheets be completed The following sequenced steps make for a quick and efficient installation With experience installers may adopt variations on these procedures that suit their particular needs 1 Connect Cables 2 Power up Unit and Verify Physical Installation ...

Page 42: ...0 to its respective terminal devices e g ordinary telephone sets and or a G3 fax machine The following table indicates the specifications for these cables Installation Data The worksheets completed in the preceding section of this guide must be on hand to perform the physical and logical installation tasks described in this and the following section Maintenance Console Software Terminal During the...

Page 43: ... 232C Cable LAN Cable With the exception of the power cable all cables must be prepared during the installation process In addition cable restraints should be installed WARNING Follow all instructions when performing cabling procedures Improper installation methods can result in damage to the KX TDA0480 and injury to installation personnel ...

Page 44: ...S 232C cable to one of the computer s com ports e g Com 1 and to the Serial Port connector on the KX TDA0480 front panel as shown in Figure KX TDA0480 serial port connection RS 232C port on the KX TDA0480 COM port on the PC 9 pin Circuit Type EIA Signal Name Pin No Pin No Signal Name Circuit Type EIA BB RD RXD 2 BA SD TXD 3 CD ER DTR 4 AB SG 5 CC DR DSR 6 CA RS RTS 7 CB CS CTS 8 2 RD RXD BB 3 SD T...

Page 45: ...he Maintenance Console Software is configured for serial communications on the port Com 1 If a port other than Com 1 is to be used the MCS serial communications parameter must be reconfigured See Section 4 7 for details RS232C Serial Cable Cross cable To COM port Personal Computer ...

Page 46: ...5 connector into the KX TDA0480 UPLINK port located on the unit s front panel Uplink connector location 2 Connect the other end of the 10BaseT cable to the remote LAN equipment e g router Ethernet switch or hub When connecting the KX TDA0480 directly to a router use a 10BaseT Cross Rollover cable Use a 10baseT straight cable to connect the KX TDA0480 to a hub or Ethernet switch IP Link Cable Strai...

Page 47: ...ity may become degraded Line repeaters can be used when long cable lengths are required Voice quality may also deteriorate when hubs are connected in tandem and tandem arrangements should never exceed more than three stages IP PBX IP PBX Router 10BaseT straight cable 10BaseT cross cable Rollover Router Switching HUB ...

Page 48: ...esentative A blinking alarm lamp indicates that the built in clock battery has been discharged and the time parameter is no longer synchronised This can occur if the unit is left without power for more than two months This condition will cease once the clock is recharged and reset This generally takes about 10 minutes See Section 4 11 Synchronise Unit Time and Date for the Maintenance Console Soft...

Page 49: ...d in this section involves the following operations 1 Initialise the unit with new IP addressing information 2 Configure unit specific parameters 3 Upload configuration files and reboot the units IP addressing and configuration parameters were discussed in detail in Section 2 2 2 of this document and the worksheets created at that time are used to perform the logical installation tasks described i...

Page 50: ...r remotely Configure OFDD VHO and DNS DAT files off line and use an FTP link to upload the configuration files to a unit Configure a unit directly over a serial connection line by line using the terminal command line interface and on line commands In this section all configuration tasks will be performed using the Maintenance Console Software Alternative methods for creating and uploading configur...

Page 51: ... unit over the LAN an Ethernet Network card using an RJ45 connector is also required The Maintenance Console Software user s interface conforms to Windows 98 Windows NT Windows 2000 or Windows XP conventions allowing users to use a mouse to pull down menus point and click items and select operational buttons to execute various operations For additional information regarding the user interface see ...

Page 52: ...achines Corporation in the United States Microsoft Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries i486 and IntelDX4 are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries All other trademarks identified herein are the property of their respe...

Page 53: ...ays for a few seconds and is then followed by the Startup Password dialogue box After a few seconds the MCS displays the Startup Password dialogue box 4 Click the mouse cursor in the Password field and type the default Password mcs then click on the OK button to display and Maintenance Console Software main directory window 2 1 The version of the software is subject to change without notice All pr...

Page 54: ...the left mouse button then select the desired item from the menu Repeat this procedure for menu items containing submenus Below the Menu bar is the Toolbar This bar contains shortcut buttons to many of the frequently used menu items When the mouse cursor is placed over a Toolbar button a definition for the button appears on the left side of the Status bar The Toolbar bar can be removed and restore...

Page 55: ...e Unit Setup Wizard The Setup Wizard is displayed by mouse clicking a Group in which to create the unit and selecting New and then Gateway or Gatekeeper or Other on the Unit Menu A shortcut method to perform the same task is to click the right mouse button over a Group icon and select New Gateway from the Pop up menu Once a unit has been setup its setup Information and its configuration Data can b...

Page 56: ...elated to one another For example they will be in the same location Groups can be created all at once or one at a time as the network setup process proceeds Use the information recorded in the Network and Unit Configuration worksheets described in Section 2 2 of this document To create new Group 1 Mouse click on the Main icon in the directory window Groups pane and select New and Group from the Un...

Page 57: ...reate new group dialogue box 2 Select the Group Name field and type a new group name Also type comments into the Comment field if desired 3 Click on the OK button to accept the information displayed in the fields or Cancel to abort the changes The MCS updates the directory window Groups pane with the new group Repeat this procedure to create additional groups ...

Page 58: ...Logical Installation 58 Installation Manual In the sample network four groups have been created ...

Page 59: ...unit s IP addressing information to match that of the existing LAN using a direct RS 232C serial cable connection The Maintenance Console Software s Unit Information Setup Wizard method for doing this is discussed in the following procedures If desired once a unit has been created using this direct method the unit setup information can be edited remotely using a network connection 1 A Gateway is t...

Page 60: ...om 1 for serial data transfer If a serial communications port other than Com 1 is being used on the computer terminal used for unit initialisation the MCS Options item must be selected from the Tools menu to reconfigure the Com port To reconfigure the serial communications port 1 Select Options from the MCS Tools menu The MCS displays the Options folders 2 In the first folder General use the Selec...

Page 61: ...Logical Installation Installation Manual 61 3 Click on the OK button to accept the new port setting Click the Cancel button to abort the change ...

Page 62: ...and select New and Gateway from the Unit menu The worksheet for this task is discussed in section 2 2 2 Network Units List Worksheet of this document Note Click the Toolbar Create Gateway icon Click the right mouse button in the Groups window pane and use the pop up New Gateway menu item The MCS then displays the first of six Unit Setup Wizard screens for the selected Group ...

Page 63: ...Logical Installation Installation Manual 63 Click the Cancel button at any Wizard screen to abort all of the edits made during the current configuration session ...

Page 64: ...ented during unit configuration 1 Select the Name field and type a name for the unit 2 Use the pull down lists to configure the three Equipment parameters Unit Version and Interface Select only BV1250GW V1 62 and BRIT QSIG respectively 3 Select the Comment field to type comments if desired 4 Click on the Next button when finished entering information or click on the Cancel button to exit the Wizar...

Page 65: ...enter the IP Address for the unit 2 Select the Subnet Mask field and enter the Subnet Mask IP address 3 Select the Route IP Address 1 field and enter the address of the primary Gateway to which the unit is connected This is usually the IP address of a router or similar network device 4 If a secondary e g backup Gateway device is used in association with the unit enter the Route IP Address 2 5 Clic...

Page 66: ...Logical Installation 66 Installation Manual Unit Setup Wizard 3 of 6 1 Click on the Next button when finished entering information or click on the Cancel button to exit the Wizard and lose all changes ...

Page 67: ...rd is to be changed select the Password field and type the new password To enhance security an asterisk symbol will be echoed in place of each character typed WARNING If a password is lost it cannot be recovered In the event of a lost password contact your maintenance staff an service office or an authorised agent 3 Select the Confirm password field and retype the new password To enhance security ...

Page 68: ...ual If the password is changed and the Password and Confirm Password values are not identical the MCS will issue an error message and redisplay screen 4 so that the password fields can be corrected The passwords must match in order to proceed ...

Page 69: ...nged select the Password field and type the new password To enhance security an asterisk symbol will be echoed in place of each character typed WARNING If a password is lost it cannot be recovered In the event of a lost password contact your maintenance staff an service office or an authorised agent 3 Select the Confirm password field and retype the new password To enhance security an asterisk sym...

Page 70: ...ual If the password is changed and the Password and Confirm Password values are not identical the MCS will issue an error message and redisplay screen 5 so that the password fields can be corrected The passwords must match in order to proceed ...

Page 71: ...e Wizard must be written directly to the unit if the unit is to be accessed using a remote e g LAN connection During subsequent remote e g LAN sessions the Unit Information Setup Wizard can be accessed using the Edit Data and Change Unit Information item on the MCS Unit menu Upload to Unit and Reboot Use the Upload to Unit and Reboot method for new units In addition to recording the unit setup inf...

Page 72: ...eration was successful An error message will be displayed if a connection could not established In addition to the upload the unit s updated OFDD VHO file will be saved and the Main Directory windows will be shown with the new unit displayed in the Units window pane During the first time configuration unit initialisation the RS 232C cable must be connected to the unit and the COM port being used o...

Page 73: ... secondary e g backup device can be created WARNING The Maintenance Console Software can only be used to configure an the Gatekeeper device To configure other Gatekeeper devices refer to the manufacturer s documentation To create a Gatekeeper device select the Group in which the device is to be located and then select the New Gatekeeper item from the Unit menu Note Click the Toolbar Create Gatekee...

Page 74: ...tallation Manual The process for setting up a Gatekeeper unit is identical to that for a Gateway unit except that the Type field is for a Gatekeeper only Refer to the Setup Wizard procedures for a Gateway to set up the Gatekeeper ...

Page 75: ...ed and then select the New Other Unit item from the Unit menu Note Click the Toolbar Create Other Unit icon Click the right mouse button in the Groups window pane and use the pop up New Other Unit menu item The information about Other Unit can be added easily to DNS DAT by selecting Other Unit item from the devices list on priority connection information display The MCS then displays the Setup Wiz...

Page 76: ...Logical Installation 76 Installation Manual ...

Page 77: ...figured for individual units using the Unit Configuration folders described later in this section This may be better when adding only a few units to an existing network To use the Common Configuration feature 1 Select a Group in the Groups Pane or from within a group select the units to be configured using the methods described earlier in this document 2 Select the Edit Common Configuration item f...

Page 78: ...anner will be applied to all units in the selected group or to the units selected in the Units Pane The new parameters will appear in the Configuration folders for each unit If a Gatekeeper unit is a member of the selected group only the SNMP parameters will be applied to that unit ...

Page 79: ...ion data for one or more units has been entered into the MCS each unit s configuration file can be saved to a hard disk and or uploaded to unit s using the network interface 1 In the procedures discussed in this section the completed configuration files will be uploaded to the units using a LAN connection See Section 3 4 for additional information about the LAN connection To begin the configuratio...

Page 80: ...for editing In the case of a newly created unit the Saved configuration file option default should be selected If a unit has been previously configured and its configuration file is not recorded on the MCS terminal currently in use it may be desirable to download the OFDD VHO file from the unit In order to do this the terminal must have an active LAN link with the unit In this case select the Down...

Page 81: ...his unit has been configured previously there may be two or more versions of the OFDD VHO file displayed The file named with the VHO extension will always be the most recent version of the configuration file stored on the MCS terminal Older backup or rollback versions of the configuration file will always be listed with the extension OLD and will be listed in data sorted order with the most recent...

Page 82: ...iguration folders for the Type of unit being configured In most cases the order in which folders are selected for data entry is not important In the few cases where order is important the MCS will issue a warning message To view a configuration folder click on a folder s tab Click the Cancel button in any folder to abort all of the edits made during the current configuration session Folder tabs ...

Page 83: ...tion data are entered The data to be entered should have already been identified and recorded on a Unit Setup Worksheet for the unit being configured Field definitions and parameter descriptions are provided in Section 2 2 of this document Much of the data recorded during the unit configuration process is critical to the proper operation of the equipment and care must be taken to avoid errors Each...

Page 84: ... IP addressing information Unit Displays the unit s name This field cannot be edited from this folder To change a unit s name exit the Edit Data configuration screen and return to the directory window Click the mouse cursor once on the Unit Name in the MCS Units windowpane When the cursor changes to a text edit cursor make the desired changes and then click the mouse over another section of the MC...

Page 85: ...into the New Password field 3 Type the new password a second time in the Confirm new password field 4 Click on the OK button Click the Cancel button to abort the operation The MCS will then close the Change Password dialogue box and return to the General folder If the current password is incorrect or if the new password confirmation does not match the new password the MCS displays an error message...

Page 86: ...ary Gateway e g router If the unit was setup on the terminal currently in use this value should not need to be changed Route Address 2 Type an IP address for the secondary backup Gateway e g router If the unit was setup on the terminal currently in use this value should not need to be changed ...

Page 87: ...nd installation of custom tone sets the following procedure is for configuring the unit with a predefined tone set Use the Tone field to select a predefined Tone set In the Information section the Tone library list shows the values for the currently selected Zone setting Tone select Use the pull down list to view available and choose a predefined Tone set ...

Page 88: ...to configure the unit numbering plan This information includes the unit s KX TDA0480 Office Code Use the Office Code section to view and edit the unit s Office Code Office Code Type the unit s 1 to 16 digit Office Code This value is required Voice Access Not usable Fax Access Not usable ...

Page 89: ...Logical Installation Installation Manual 89 Access Code Dialling Not usable ...

Page 90: ...Numbering2 Folder Use the Numbering2 folder to set the Originate side called party number conversion information Before conversion Enter edit Before conversion number max 32 digits After conversion Enter edit After conversion number max 32 digits ...

Page 91: ...ng3 folder to set the Receiver side called number conversion information Before conversion Enter edit Before conversion number max 16 digits After conversion Enter edit After conversion number max 16 digits Special number Specify a number to add when the called number is entered ...

Page 92: ...onfiguration As discussed latter the Hunt Pattern folder can be used to specify a priority order in which these groups are accessed The Port parameters list displays the configuration parameters for each unit port If the list columns exceed the width of the list window use the horizontal scroll bar to move the display to the right or left Also the column widths can be adjusted by placing the mouse...

Page 93: ... Length of Call Reference Set to 1 all the time Interface Type Set to Basic Interface all the time PAD In Use the pull down list to select the PAD value in dB to be applied to voice signals coming into the unit It is usually best to use the default value for this field until it is determined by observation that adjustments are required PAD Out Use the pull down list to select the PAD value in dB t...

Page 94: ...ocol Type Set a type of the ISDN Layer 3 signal protocol or a call control signal Only QSIG is supported DTMF transfer signal pattern Set DTMF signalling method Auto Alphanumeric Signal Complete the fields listed above for each active port on the unit If a port on the unit is inactive select the port in the Port parameters list and click on the Clear button to logically disable the port If this is...

Page 95: ...s defined then the Trunk Priority features are used to configure the priority order in which alternate Trunk Groups are searched in the event that a connection cannot be established within first group To configure a Hunt Pattern complete the fields located beneath the Patterns list and click the Update button Once the Update button is clicked the new Pattern list will be updated with the new Patte...

Page 96: ... circumstances assign the same value as the value assigned for the PBX code at the PBX to this parameter 8 digits maximum per code Hunt Pattern No Use the pull down list to select the Hunt Pattern No 1 or 2 to be associated with the Destination number field ...

Page 97: ...nd on the associated Trunk Group then the remaining group is searched in priority order Up to 2 Hunt Patterns can be defined for each unit The Hunt Pattern list provides records for each Hunt Pattern that was defined in the Hunt Patterns folder To configure a Hunt Pattern select the desired pattern in the Hunt Pattern list and complete the fields located beneath the Hunt Pattern list The Hunt Patt...

Page 98: ...ation 98 Installation Manual Trunk group number Use the pull down list to select a Trunk Group 1 or 2 to be associated with the Priority settings Only Trunk Groups that were defined in the Trunk Data folder are listed ...

Page 99: ...ion list are read only fields for Packet parameters Packet size and bandwidth To configure a port s Voice Mode select the port to be configured on the Configuration list and then modify the protocol field below the list using the Select protocol field The Packet parameters are modified using the Efficiency slide bar on the right side of the dialogue box The Configuration list and read only Packet ...

Page 100: ...t To operate the Packet send interval slide bar click on the control handle and hold the mouse button Drag the control handle to the left or right to adjust the ratio The values in the read only Packet parameter fields are updated as the slide bar is manipulated CODEC Information Use the Up arrow and Down arrow to configure the Codecs on the Configuration list Select the Codec s to be applied for ...

Page 101: ...e same Even when connecting to other company products the protocol can be used in the same manner if the specifications are the same FAX capability The configuration can be selected from TCP and UDP Redundant Default setting is TCP Left window Protocol used The priority level of the protocol is specified Right window Protocol which can be used The protocol not immediately used is specified Up Down...

Page 102: ...ent Bit order Data for specifying the send sequence of bit arrays when sending T 38 packet data When sending as advised specify the normal direction When reversing the send sequence of bit arrays specify the reverse direction Selection will be made according to the conditions of the other party s device The default setting is the reverse direction IFP packet max size Maximum size of IFP Internet F...

Page 103: ... network timing parameters Regular time period Type the timing cycle over which the error checking packets will be transmitted during normal operation The seconds value can also be scrolled up and down with the scrolling arrows located to the right of the field Error detect time period Type the timing cycle over which the error checking packets will be transmitted after an error has been detected ...

Page 104: ...s that an error can be detected before the link is failed The Times value can also be scrolled up and down with the scrolling arrows located to the right of the field Reconnect after errors Type the number of times that a recovered link is to be detected before the link will be reestablished as normal The value can also be scrolled up and down with the scrolling arrows located to the right of the ...

Page 105: ... Use the Information section fields to modify the H 245 call start and signalling parameters RTP start parameters T 38 call start and connection timing Call signalling port number Type the number of the port on which transmission will occur The default port number is 1720 From 4 to 65524 can be specified except FTP 20 21 telnet 23 ports The default values conform to the H 323 protocol and should a...

Page 106: ...port number is 5012 From 4 to 65521 can be specified except FTP 20 21 telnet 23 ports The port number can also be scrolled up and down with the scrolling arrows located to the right of the field UDP Port No Supplementary service A port used to transfer QSIG signals in an IP network when they are received using the QSIG connectionless supplementary service The default port number is 5003 From 4 to ...

Page 107: ...er translation Modifications to DNS are described in A3 DNS Configuration This information is recorded on the Common Configuration worksheet described in Section 2 2 4 Common Configuration Worksheet of this document and can also be entered for selected unit groups using the Edit Data Edit Common Configuration items on the Unit menu See Section 4 8 for the procedure using the Common Configuration f...

Page 108: ...its it will start number translation Set this data value to 1 when it is configured in priority connection information that IP address will be determined by 1 digit The default value is 1 digit The digits value can also be scrolled up and down with the scrolling arrows located to the right of the field DNS file format Not usable IP address for DNS 2 Not usable IP address for DNS 3 Not usable Acces...

Page 109: ...on is recorded on the Common Configuration worksheet described in Section 2 2 4 Common Configuration Worksheet of this document and can also be entered for selected unit groups using the Edit Data Edit Common Configuration items on the Unit menu See Section 4 8 for the procedure using the Common Configuration facility in the Maintenance Console Software IP address for Trap Transmission 1 Type the ...

Page 110: ...ternet Protocol addressing requirements IP address for Trap Transmission 3 Type the IP address for a third Trap Transmission facility The IP address must conform to Internet Protocol addressing requirements Community name Type the SNMP Community Name The name may consist of a string of from 1 to 8 characters e g public proxy private etc The default value is the name public ...

Page 111: ...n this case no entries are required for Gatekeeper devices This information is recorded on the Common Configuration worksheet described in Section 2 2 4 Common Configuration Worksheet of this document and can also be entered for selected unit groups using the Edit Data Edit Common Configuration items on the Unit menu See Section 4 8 for the procedure using the Common Configuration facility in the ...

Page 112: ...for registration when Gatekeeper is selected and entered H 323 ID Set H 323 ID format for alias to register with Gatekeeper Gatekeeper 1 Type the IP address for the first primary Gatekeeper The IP address must conform to Internet Protocol addressing requirements Gatekeeper 2 Type the IP address for the second secondary Gatekeeper The IP address must conform to Internet Protocol addressing requirem...

Page 113: ...re the Recovery delay settings for the unit Maximum receive Buffer size Type or scroll to the maximum allowable size of the recovery buffer In most cases the default size 1920 ms will provide the best results Start recovery Type or scroll to the duration of the network interruption after which voice data should be retrieved from the recovery buffer In most cases the default value 200 ms will provi...

Page 114: ... which event notifications will be sent This information is recorded on the Common Configuration worksheet described in Section 2 2 4 Common Configuration Worksheet of this document and can also be entered for selected unit groups using the Edit Data Edit Common Configuration items on the Unit menu See Section 4 8 for the procedure using the Common Configuration facility in the Maintenance Console...

Page 115: ...er The IP address must conform to Internet Protocol addressing requirements e g nnn nnn nnn nnn where nnn a value of 0 to 255 excluding 0 0 0 0 and 255 255 255 255 Email Address 1 Type the e mail address to which unit event notifications are to be sent Email Address 2 If desired type a second e mail address to which unit event notifications are to be sent ...

Page 116: ...the Priority routing information folder to setup ToS Type of Service field of IP header Use the Information section fields to setup HEX ToS and DiffServ HEX Specify HEX field priority control b7 b0 ToS Priority View priority level Delay View delay priority Speed View throughput priority ...

Page 117: ...Logical Installation Installation Manual 117 DiffServ DS field priority control DSCP F View DSCP Hex range 6 bit MSB Reliance View reliance priority Expenses View cost priority ...

Page 118: ... conditions Use the A law m law flag to configure the PCM coding and compression standard to be used by the unit Finish Gateway Configuration Once all of the configuration parameters have been configured in the Maintenance Console Software click on the OK button located at the bottom of the folders display Cause of Fan Fault Ignore this parameter A law m law Flag m law A law default m law ...

Page 119: ...displays a confirmation dialogue box Select Yes to abandon all changes and return to the directory window Note Often when many units need to be created and configured several of the units will have similar configurations When this is the case a quick way to create and configure these additional units is to use the copy and paste commands to create copies of existing units Once created copied units...

Page 120: ... on the Unit menu and select Change Unit Information to modify the setup parameters Finally use the Edit Data item on the Unit menu and select Edit configuration to modify the unit s configuration The Cut Copy and Paste features are also displayed on the Unit s pane pop up menus Use these features to delete units make copies of units and move units from one group to another ...

Page 121: ... care must be taken to avoid errors As discussed earlier when a unit is selected and the Edit Data command is used the Maintenance Console Software asks if a saved file is to be edited or if the file in the unit should be downloaded If the saved file is to be edited the Maintenance Console Software displays a dialogue box in which the file to be edited can be selected See section 4 7 Create New Un...

Page 122: ...it s name This field cannot be edited from this folder To change a unit s name exit the Edit Data configuration screen and return to the directory window Click the mouse cursor once on the Unit Name in the MCS Units windowpane When the cursor changes to a text edit cursor make the desired changes and then click the mouse over another section of the MCS window The change made will be reflected in t...

Page 123: ...sword dialogue box and return to the General folder If the current password is incorrect or if the new password confirmation does not match the new password the MCS displays an error message Use the IP Addresses section to view and edit unit IP addressing information IP Address Type an IP address for the KX TDA0480 If the unit was setup on the terminal currently in use this value should not need t...

Page 124: ...stallation 124 Installation Manual Route IP Address 2 Type an IP address for the secondary backup Gateway e g router If the unit was setup on the terminal currently in use this value should not need to be changed ...

Page 125: ...king packets will be transmitted during normal operation The seconds value can also be scrolled up and down with the scrolling arrows located to the right of the field Error detect time period Type the timing cycle over which the error checking packets will be transmitted after an error has been detected This value is usually set to a higher frequency than Regular Timing If a normal return is dete...

Page 126: ... be reestablished as normal The times value can also be scrolled up and down with the scrolling arrows located to the right of the field Gatekeeper ID Type the unit ID number for the Gatekeeper Other Gatekeeper IP address If a another Gatekeeper is installed in the network type the IP address of the other unit Use bandwidth management Click on the radio button indicating that bandwidth management ...

Page 127: ... groups using the Edit Data Edit Common Configuration items on the Unit menu See Section 4 8 for the procedure using the Common Configuration facility in the Maintenance Console Software When a Gateway unit is selected for Edit Common Configuration the only values applied are those configured for SNMP All other Common Configuration parameters are ignored IP Address for Trap Transmission 1 Type the...

Page 128: ...IP address for a third Trap Transmission facility The IP address must conform to Internet Protocol addressing requirements Community name Type the SNMP Community Name The name may consist of a string of from 1 to 8 characters e g public proxy private etc The default value is the name public ...

Page 129: ...Then click on the name of the last unit in the list while holding the shift key To select non contiguous group of units hold the CTRL key and then click on the name of each unit to be selected To perform the upload using the following Maintenance Console Software procedure the unit setup parameters must have been previously uploaded to the unit using the Unit Information Setup Wizard s Upload Opti...

Page 130: ... units will automatically be rebooted 5 If desired check the Log activity option to record a log of the transfer process Use the radio buttons to have the file overwrite any existing log files or append the log data to the end of an existing file 6 Click on the OK button to begin the file transfer Click the Cancel button to abandon the file transfer process The Maintenance Console Software display...

Page 131: ...ansfer process is complete the Maintenance Console Software displays a report The Configuration file column should show OFDD VHO for each unit All other columns should show a dashed line If the transfer process failed the Configuration file column will show a value of NG No Good See the KX TDA0480 Programming Guide for a discussion of trouble shooting ...

Page 132: ... files have been successfully transferred each of the units must be rebooted to have the new configurations take effect If the Reboot option was not selected during the file transfer process the units can be rebooted using the Control Reboot item on the Unit menu ...

Page 133: ...n the list while holding the shift key To select non contiguous group of units hold the CTRL key and then click on the name of each unit to be selected The Maintenance Console Software displays a Reboot dialogue box allowing the reboot to be forced or causing the reboot to occur only after all in process calls are terminated 2 Click the radio button for the desired option and click the OK button t...

Page 134: ...to proceed with the reboot Select the Cancel button to abandon the process The Maintenance Console Software displays a confirmation dialogue box 4 Click Yes to proceed with the transfer or cancel to abandon the process Once the Maintenance Console Software completes the operation a Reboot results list is displayed The Result column should display OK If Error is returned for a unit there was a prob...

Page 135: ...used to synchronise the KX TDA0480 s time and date with the time and date setting of the computer terminal with which the unit is connected To update the time and date settings for one or more units 1 Check that the time and date setting for the computer terminal is correct and reset the time if necessary 2 Select the Time sync command from the Unit menu 3 The MCS displays a Time sync unit selecti...

Page 136: ... Installation 136 Installation Manual The MCS displays a message box showing the progress of the update and then displays a results list indicating if the process was successful for each of the selected units ...

Page 137: ...Appendices Installation Manual 137 Appendix A Appendices ...

Page 138: ...network location has a subnet mask address that helps to define which digits of an IP address are used for the network address and the host address In this case the sample network the subnet address is the KX TDA0480 default 255 255 255 0 The subnet mask addresses for various networks may differ from the default subnets In the case of the Internet the subnet mask address will be provided by the re...

Page 139: ...h KX TDA0480 has a sequential number For example at the New York office are addressed in sequence so that the last element of the NY01 address is 91 NY02 is 92 This sequencing is for convenience only and is not a requirement of the addressing scheme Finally each location in the sample network has only a single router Of course there may be more than one router at each location and each must be ser...

Page 140: ... PBX to PSTN in each IP PBX A2 2 Dialling Examples The following examples describe the digits to be dialled when placing a call from various locations in the sample network Trace the call paths listed here on the sample network diagram to better understand the sample numbering plan Router PBX PSTN PSTN PSTN New York Main Office Los Angels Branch Office San Francisco Branch Office IP PBX PBX Code 5...

Page 141: ...os Angeles PSTN number 213 555 9999 dial IP Trunk Access Code LA PBX Code PSTN Trunk Access Code LA PSTN Number 76 61 9 213 555 9999 To call New York Extension 599 dial IP Trunk Access Code NY PBX Code NY PBX Extension 80 21 599 To send a fax to New York office dial IP Trunk Access Code NY PBX Code NY PBX Fax Extension 80 21 701 To call New York Extension 101 dial IP Trunk Access Code NY 2nd PBX C...

Page 142: ...ged A3 2 KX TDA0480 Internal DNS Database The internal DNS DAT file is a simple text based database file Each line in the file is a record containing number translation information for the KX TDA0480 in a network sharing the same domain Within each record fields are identified by a single letter Following each field identifier the field values are recorded The fields in the DNS DAT file are N Call...

Page 143: ... PBX 21 The Hunt Pattern is 91 92 Hunting for channel on PBX 27 is only 92 The DNS DAT database for the preceding configuration is PBX IP PBX PBX Code 51 Extensions 60 69 PSTN Trunk Access Code 9 PBX IP PBX PBX Code 61 Extensions 200 299 PSTN Trunk Access Code 9 N 215 R2 I 133 149 1 91 1720 I 133 149 1 92 1720 N 217 R2 I 133 149 1 91 1720 I 133 149 1 92 1720 N 219 R10 I 133 149 1 91 1720 I 133 149...

Page 144: ...ation is arranged in this manner it will take longer to connect a call since dialling does not start until the inter digit time out 5 sec has occurred after dialling the extension or a fax number I 133 149 1 91 1720 I 133 149 1 92 1720 Specifies the IP address of the KX TDA0480 adjacent to PBX Code 21 N 215 Specifies the extension number 5nn R value being 2 500 599 of PBX Code 21 as a called desti...

Page 145: ...as those described in the preceding example Any traffic to and from PBX Code 27 will use only the NY02 C N 516 R 1 I 206 184 223 95 1720 N 519 R 10 I 206 184 223 95 1720 Line C provides translation information for terminating a call at PBX Code 51 D N 612 R 2 I 200 45 11 34 1720 N 619 R 10 I 200 45 11 34 1720 Line D provides translation information for terminating a call at PBX Code code 61 ...

Page 146: ...k wide basis In most cases it should not be necessary to modify the default PAD In and PAD Out settings Indications that some adjustment is required are The following issues should be considered when adjusting the pad control The digital pad value for the KX TDA0480 can be selected as 40 38 c 14 12 10 8 6 4 2 0 2 4 6 8 10 12 14 dB The unit default settings are PAD Out 0 dB PAD In 0 dB A4 2 AGC Whe...

Page 147: ...high The gain control feature operates on both the incoming and outgoing sides and is referred to as the PAD control The KX TDA0480 is able to optimise the gain or loss level of the voice signals In most cases it should not be necessary to modify the default PAD In PAD value of the voice signals coming in to the unit PAD Out PAD value of the voice signals going out from the unit settings Indicatio...

Page 148: ...below the KX TDA0480 is located as close to the WAN interface as possible Priority Control Some routers permit the configuration of priority control features This allows the router to be configured to give higher priority to packets with high priority flags The priority control feature should be used when available The KX TDA0480 port numbering for the various packet types is presented in the foll...

Page 149: ...ng that the buffer is full End Recovery defines the limit beneath which the buffer continues to discard packets until the setting is reached The following diagram illustrates how the buffer process works 6 ISDN Service 5003 UDP 7 SNMP 161 UDP 8 T38 5012 5013 5014 5015 TCP 9 FTP for data 20 TCP 10 T38 5012 5013 5014 5015 UDP 11 SMTP 25 TCP Port No is the logical number used to manage the category o...

Page 150: ... KX TDA0480 uses 12K per port when in use Serialisation delays to the WAN are lower when higher bandwidths are used When using the Internet VPN the Internet Service Provider plays an important role in reducing the variable delay in the WAN A regional or national ISP will usually have better connectivity with the backbone and will be able to guarantee greater service reliability than a local city I...

Page 151: ...IP address of firewall becomes the Default Gateway IP address to be associated with the KX TDA0480 Also when installing the IP Gateway network within a firewall voice and fax packets must be routed through specified firewall ports using the information in the following table Item No Type of Communication Port No TCP UDP Priority Control Assignment Recommended 1 Q 931 1720 TCP Priority 2 H 245 1721...

Page 152: ...7 SNMP 161 UDP Normal 8 T38 5012 5013 5014 5015 TCP Priority 9 FTP for data 20 TCP Normal 10 T38 5012 5013 5014 5015 UDP Priority 11 SMTP 25 TCP Normal Item No Type of Communication Port No TCP UDP Priority Control Assignment Recommended ...

Page 153: ...g the MCS Setup Wizard Section 4 7 Create New Units using the IP addressing information for the unit Finally select the download option when configuring the unit Section 4 7 Create New Units and download the configuration data directly from the unit The manually created settings will then appear in the MCS configuration folders Also when working directly with configuration files it is very importa...

Page 154: ...PASS_M 3014163d2c121e16110b1a Maintenance Password Max 10 Digits PASS_U 3014163d2c0a0c1a0d Generic Password Max 10 Digits VHUB_AREA US Zone P1 Zone JP Japan US North America EU Europe AUDIO_CAP 1 2 Audio capability priority seq i1 G 729A 2 G 723 1 6 3kbps j FAX_CAP 1 2 FAX capability type priority seq 1 TCP 2 UDP Redundant FAXREDUNDANT 0 FAX Redundant no 0 DTMF_TYPE 0 DTMF transfer method automati...

Page 155: ...hen manually configuring a large number of units In this case experienced installers can download a OFDD VHO file manually edit its configuration parameters for another unit and then upload the new configuration file to the new unit A OFDD VHO file can be downloaded from a unit and then edited manually A manually edited OFDD VHO file created and saved either manually or with the Maintenance Consol...

Page 156: ...hoed on the screen and the terminal window displays a confirmation of login 230 User mainte logged in Configuration File Download Use the following procedure to download a DNS DAT or OFDD VHO file from the KX TDA0480 using an FTP session 1 To access the OFDD VHO file directory type following command at the FTP prompt and press the Enter key ftp cd VHUB OFD The FTP terminal displays a confirmation ...

Page 157: ...file directory type following command at the FTP prompt and press the Enter key ftp cd ETC The FTP terminal displays a confirmation of the directory change 250 CWD command successful 5 At the FTP prompt type the GET command and press the Enter key to retrieve the DNS DAT file ftp get DNS DAT 200 PORT command successful 150 Opening ASCII mode data connection for DNS DAT 58 bytes 226 Transfer comple...

Page 158: ...fer complete 4236 bytes sent in 0 00 seconds 4236000 00Kbytes sec 3 At the FTP prompt type the CD command to return to the KX TDA0480 s root directory ftp cd The FTP terminal displays a confirmation of the directory change 250 CWD command successful 4 To access the DNS DAT file directory type following command at the FTP prompt and press the Enter key ftp cd ETC The FTP terminal displays a confirm...

Page 159: ...mpt type the BYE command following command and press the Enter key ftp bye 221 Goodbye C 7 Type EXIT at the C prompt to end the Windows DOS session Use the shutdown procedure described in Section 4 9 and then restart the unit to have the new configuration settings take effect in the target unit ...

Page 160: ... worksheets are described in Section 2 2 of this document They are provided here as reproduction masters or templates IP Gateway Network Units List Worksheet Group Name Unit Name Unit IP Address Subnet Mask IP Address Route IP Address 1 Route IP Address 2 Signal port no ...

Page 161: ...mmon Configuration Worksheet Group Name s DNS SETUP Search Digits 2 SNMP Setup Trap 1 IP Trap 2 IP Trap 3 IP Community Name public Gatekeeper Gatekeeper 1 IP Gatekeeper 2 IP Notify E mail SNMP Primary IP SNMP Secondary IP E mail 1 E mail 2 ...

Page 162: ...ng AGC dBm Disabled Protocol Type QSIG Port 1 Port 2 Pattern 1 Pattern 2 Destination No PBX Code Hunt Pattern No 1 or 2 For additional items use extension from BR A Priority 1 Trunk Group No Priority 2 Trunk Group No 1 Port 1 Port 2 Protocol H 323 Qual Effic Payload 80byte Qual Effic Bandwidth 12 0K bps Primary CODEC G 729a Secondary CODEC G 723 1 Regular Timing 0 Disconnect on Errors 10 Error Det...

Page 163: ...anual 163 KX TDA0480 Unit Setup Worksheet Extension Group Name Unit Name HUNT PATTERN Destination No PBX Code Hunt Pattern No 1 or 2 BR A Use this section to list additional Hunt Pattern data Use additional worksheets if needed ...

Page 164: ...Appendices 164 Installation Manual ...

Page 165: ...ring DTMF signals on an IP network Although the purpose of this method is to transfer keypad input information DTMF signals can also be transferred For the KX TDA0480 the method is selected when the communicating party is H 245 V3 or later Audible signal tones Audible signal tones are identification tones used to control the connection process or provide status to telephone calling and called part...

Page 166: ...pability of Gatekeeper priority Connection procedure dependent of Gatekeeper only during address conversion Although there is little Gatekeeper load the communication status of the Gatekeeper cannot be managed completely DNS function A number dialled by a telephone set is converted into an IP address The IP address is the number used to actually set up a call over an IP network DNS information Thi...

Page 167: ...IP Internet Protocol IP protocol is widely used in Internet and LAN networks The purpose is to deliver data between computing equipment over the network The protocol is generally effective but does not guarantee complete and accurate data communications IP Address A number used to identify the location of a host device It is expressed in numeric dot notation e g 202 203 27 31 Local Area Network A ...

Page 168: ...erating system The software provides a graphical user interface GUI for installing and maintaining the KX TDA0480 and for configuring the KX TDA0480 internal network features MCS connection with the KX TDA0480 is accomplished directly using an RS 232C cable or remotely over a LAN connection Numbering plan In a communications network a numbering plan allocates specific numeric codes to identify eac...

Page 169: ...ice tones Port number A port number is a logical number that manages the category of service supported and resources used in the TCP UDP protocol The port number is referred to when setting the priority control of a router Priority connection information In the KX TDA0480 DNS information stored in the unit is referred to as priority connection information Priority control When a packet to which a ...

Page 170: ...ekeeper load logs can be collected accurately for accounting purposes etc since the communication status can be grasped completely Signal method Encoding method of H 245 when transferring DTMF signals on an IP network The purpose of this method is to transfer DTMP signals The transmission time of DTMF signals can be specified on the receiving side not available on the KX TDA0480 For the KX TDA0480...

Page 171: ... in the event of an equipment fault for diagnostic purposes TRS OKI proprietary feature that allows Gatekeeper units to be configured by a system administrator for routing groups among the stacked cascaded KX TDA0480 UDP User Datagram Protocol An unreliable networking layer that sits at the same level of the networking stack at TCP Unreliable Transmission Connection less transmission which provide...

Page 172: ...2 Installation Manual Zone A collection of all H 323 Terminals Gateways and MCUs managed by a single H 323 Gatekeeper A zone must include at least one Terminal and may include LAN segments connected using routers ...

Page 173: ...Glossary Installation Manual 173 ...

Page 174: ...copyrighted by Panasonic Communications Co Ltd PCC You may print out this manual solely for internal use with this model Except above you may not reproduce this manual in any form in whole or part without the prior written consent of PCC 2003 Panasonic Communications Co Ltd All Rights Reserved PSQX2538ZA KK0103AH0 ...