Network Folder
Use the Network folder to configure the network timing parameters used to monitor the link
between a Gateway and router, hub, or switching device to which the unit is connected. When
link failure is detected, the error condition is reported.
Use the Information Section to view and edit the network timing parameters.
Regular time period
Type the timing cycle over which the error checking packets will be transmitted during normal
operation.
The seconds value can also be scrolled up and down with the scrolling arrows located to the
right of the field.
Error detect time period
Type the timing cycle over which the error checking packets will be transmitted after an error
has been detected. This value is usually set to a higher frequency than Regular Timing. If a
normal return is detected during this period, the Regular Timing is resumed.