Physical Installation
48
Installation Manual
3.5
Power-Up the KX-TDA0480 and Verify Operation
Front panel indicators
•
Operation, On-line, Alarm, and Busy lamps light up during the initialisation process.
•
The Alarm and Busy lamps turn off following initialisation and the Operation and On-line
lamps remain lit.
If the Alarm and/or Busy lamps remain lit for more than five minutes, turn the unit power OFF
and contact an authorised PANASONIC representative.
•
A blinking alarm lamp indicates that the built-in clock battery has been discharged and the
time parameter is no longer synchronised. This can occur if the unit is left without power
for more than two months. This condition will cease once the clock is recharged and reset.
This generally takes about 10 minutes. See Section 4.11
Synchronise Unit Time and Date
for the Maintenance Console Software clock reset procedure.
IF the KX-TDA0480 is connected to the ethernet network, the "Link" lamp will also light
up.
Operation (LED1)
On-line(LED2)
Alarm(LED3)
Busy(LED4)
Link(LED5)
Data(LED6)
Collision(LED7)
SIOSEL(LED8)
Uplink Connector
Serial Port