3.3 Data Management
Programming Guide
59
Firmware Status
shows the current firmware status of page 0 and page 1, and
Startup
Page
shows the current active page on startup. For details about these parameters, refer to
"3.3.2 Handling of Firmware Page".
3.
Do the following to update the desired page with the uploaded firmware data:
a.
Click the option for the page whose current firmware status is not "Main Operation Mode"
for
Select Page
.
b.
Click
OK
.
You will see a confirmation screen.
c.
Click
OK
.
4.
Do one of the following:
•
Click
REBOOT
to start up the VoIP Gateway Card with the updated page and confirm that
the upload operation has been carried out successfully.
You will see a reboot confirmation screen. Refer to "3.4.1 Reboot" and finish the reboot.
Note
After the reboot, the card starts up with the updated page temporarily so that you can
confirm the result of the upload operation. If you reboot again, the card does not start
up with the updated page, but starts up with the page whose current firmware status is
"Main Operation Mode".
•
Click
CANCEL
to return to the main menu without starting up the card with the updated
page.