3.2 Maintenance
Programming Guide
59
3.2
Maintenance
3.2.1
Status Control
1.
Click
1.1 Change RUN/STOP status
in the main menu.
Current RUN/STOP Status
shows the current status of the VoIP Gateway Card.
2.
Click
RUN
or
STOP
for
Status after changing
.
If you want to forcibly change the status from "RUN" to "STOP" while there are ongoing calls,
click the
Yes
check box for
Forced Disconnect when executing STOP
. This will allow you to
place the card in the "STOP" status even when there are ongoing calls.
At any time during the session, you can:
•
Click
MENU
to return to the main menu (see "3.1 Main Menu for the Installer").
•
Click
LOGOUT
to log out from the IP-GW16 Maintenance Utility (see "3.4.2 Log Out").
3.
Click
OK
.
You will see a confirmation screen.
4.
Click
OK
.
You will see a result screen.
Note
If the operation is not successful, you will see an error screen. Click
OK
to return to the
previous screen, and then try again.
5.
Click
OK
.
You will be taken back to the
Change RUN/STOP status
screen.