Power Supply Unit Capacity
Calculate the load figure from the type and number of items of equipment to be connected.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
IP-PT
0
Trunk Card
DID8
16
E&M8
8
Others
0
Extension Card
MCSLC16
16
MCSLC24
24
CS (1 unit)
4
PT-interface CS (1 unit)
4
PT-interface CS (High-density) (1 unit)
8
ISDN Extension
2
VPS (1 port)
1
*1
Only the extension cards that can support SLTs count for the load figures.
Maximum Load Figure
The pre-installed power supply unit (PSU) supports the following load figures.
System Equipment
Maximum Load Figure
Any Equipment
104
Additional Load Capacity for a MCSLC16/
MCSLC24 Card
24
Total
128
In addition to any combination of equipment totalling a load figure of up to 104, one additional MCSLC16 card
(load figure: 16) or one MCSLC24 card (load figure: 24) may also be added, for a total load figure of up to 128.