4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Non Blocking Distributed Time Switch
Power Input
PSU-M
(KX-TDA0104)
100 V AC to 130 V AC/200 V AC to 240 V AC, 2.5 A/1.4 A, 50 Hz/60 Hz
PSU-L
(KX-TDA0103)
100 V AC to 130 V AC/200 V AC to 240 V AC,5.1 A/2.55 A, 50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, battery capacity of 28 Ah or below recommended for 1 external
battery)
Maximum Power Failure Tolerance
300 ms (without using backup battery)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non condensing)
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -6 dB to +3 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
KX-TDA200
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Weight (when fully mounted) KX-TDA200
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
·
PT: KX-T76xx series and KX-T7560/KX-T7565: 90
Ω
; all other DPTs/APTs: 40
Ω
·
SLT: 600
Ω
including set
·
Doorphone: 20
Ω
·
CS: 130
Ω
Minimum Leakage Resistance
15000
Ω
maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of a PT and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω
maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
Paging Terminal Impedance
600
Ω
MOH (Music on Hold) Terminal Impedance
10000
Ω
6
KX-TDA200BX
Summary of Contents for KX-TDA200BX
Page 8: ...5 SYSTEM OVERVIEW 5 1 SYSTEM CONFIGURATIONS 8 KX TDA200BX ...
Page 10: ...5 3 SYSTEM CONNECTION DIAGRAM 10 KX TDA200BX ...
Page 17: ...8 2 SYSTEM CONTROL 8 2 1 System Control Block Diagram 17 KX TDA200BX ...
Page 18: ...8 2 2 Voice TDM Highway Bus Block Diagram 18 KX TDA200BX ...
Page 21: ...8 3 2 EC Bus System Connection Diagram 21 KX TDA200BX ...
Page 33: ...11 3 MPR CARD 11 3 1 Startup Run indicator LED201 33 KX TDA200BX ...
Page 36: ...Optional service cards cannot start up 36 KX TDA200BX ...
Page 37: ...11 3 2 Phone Call The call path cannot connect Noise is created 37 KX TDA200BX ...
Page 38: ...11 3 3 Paging No sound PAGING1 No sound PAGING2 38 KX TDA200BX ...
Page 39: ...Noise is Heard PAGING1 Noise is Heard PAGING2 39 KX TDA200BX ...
Page 40: ...Sound is small PAGING1 Sound is small PAGING2 40 KX TDA200BX ...
Page 41: ...11 3 4 MOH Using No sound is heard MOH1 41 KX TDA200BX ...
Page 42: ...No sound is heard MOH2 42 KX TDA200BX ...
Page 43: ...Sound is small or loud MOH1 Sound is small or loud MOH2 43 KX TDA200BX ...
Page 44: ...11 3 5 USB Connection Unable to connect 44 KX TDA200BX ...
Page 45: ...Connection error occurs 45 KX TDA200BX ...
Page 46: ...11 3 6 RS 232C Connection Unable to connect 46 KX TDA200BX ...
Page 47: ...Connecting speed is slowly 47 KX TDA200BX ...
Page 48: ...11 3 7 SD Card I F Unable to save the system data 48 KX TDA200BX ...
Page 49: ...11 3 8 Other The clock data is deleted unset table 49 KX TDA200BX ...
Page 59: ...12 2 DIAGNOSIS TEST 1 Click Diagnosis of Utility 59 KX TDA200BX ...
Page 60: ...2 Pair Port Test operation Select card for Test 3 Click Pair Port Test 60 KX TDA200BX ...
Page 61: ...4 Click OK 5 Click Cancel 61 KX TDA200BX ...
Page 62: ...6 Card Test operation Select card for Test 7 Click Card Test 62 KX TDA200BX ...
Page 63: ...8 Click OK 9 Click Cancel 63 KX TDA200BX ...
Page 68: ...14 TERMINAL GUIDE OF ICS TRANSISTORS AND DIODES 68 KX TDA200BX ...
Page 70: ...16 CABINET AND ELECTRICAL PARTS LOCATION 70 KX TDA200BX ...
Page 71: ...16 1 EXTENSION BOARDS FOR SERVICING 71 KX TDA200BX ...
Page 72: ...17 ACCESSORIES AND PACKING MATERIALS 72 KX TDA200BX ...
Page 91: ...Waveform 7 Waveform 8 20MHz 12MHz KX TDA200BX 91 ...