2.7 [1] Configuration
PC Programming Manual
125
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T301
Specifies the maximum time that the PBX waits for a reply after making a call to ISDN.
Default
0 × 100 ms
Value Range
0–18000 × 100 ms
Maintenance Console Location
2.7.13 [1-1] Slot—PRI Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T302
Specifies the maximum time allowed between each digit on an incoming call. Applies to overlap
receiving.
Default
150 × 100 ms
Value Range
0–600 × 100 ms
Maintenance Console Location
2.7.13 [1-1] Slot—PRI Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References