2.7 [1] Configuration
PC Programming Manual
171
Programming Manual References
None
Feature Manual References
None
Flash—Minimum BREAK Width (TIE)
Specifies the minimum length of the break signal in a flash signal sent from a TIE line.
Default
200 ms
Value Range
8 × n (n=3–63) ms
Maintenance Console Location
2.7.16 [1-1] Slot—T1 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Flash Width (TIE)
Specifies the maximum length of a flash signal received from a TIE line that the PBX can recognize
as a hookswitch flash signal.
Default
800 ms
Value Range
8 × n (n=3–191) ms
Maintenance Console Location
2.7.16 [1-1] Slot—T1 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Caller ID—Caller ID Start Code
Selects the DTMF code used to detect the beginning of a Caller ID series.