2.8 [2] System
226
PC Programming Manual
Value Range
0–15
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
1.15.1 Redial, Last Number
Automatic Redial—Redial Call Ring Duration (KX-TDA100/KX-TDA200/KX-
TDA600 only)
Specifies the length of time that the PBX waits for the called party to answer an Automatic Redial
attempt. This is the length of time that the called party's extension will ring for each attempt.
Default
30 s
Value Range
10 × n (n=1–30) s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
1.15.1 Redial, Last Number
Automatic Redial—Analog CO Mute / Busy Detection Timer (KX-TDA100/KX-
TDA200/KX-TDA600 only)
Specifies the length of time before the PBX stops muting the caller's voice and cancels busy tone
detection when Automatic Redial to analog CO line is performed.
Default
8 s
Value Range
0–15 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters