2.11 [5] Optional Device
PC Programming Manual
589
, = 100–1300 ms, =
90 ms, =
90 ms
Option: The tone pattern that the PBX receives is optional as specified in
SVM Cyclic Tone Option
on this screen.
Maintenance Console Location
2.11.5 [5-3-3] Voice Message—SVM (KX-TDA50 only)
Programming Manual References
None
Feature Manual References
1.16.5 SVM (Simplified Voice Message)
SVM Cyclic Tone Option—Tone On Maximum Time
Specifies the maximum duration of the cyclic tone that will be recognized by the PBX. When the tone
sent from the telephone company is shorter than the value set here, the PBX recognizes it as a tone-
on.
Note that this option can only be set when
SVM Cyclic Tone Detection
on this screen is set to
"Option".
To apply changes to this setting, follow the steps below:
1.
Change this setting.
2.
Set the status of the SVM2 card to "
OUS
", then "
INS
".
Default
600 ms
Value Range
20 × n (n=6–200) ms
Maintenance Console Location
2.11.5 [5-3-3] Voice Message—SVM (KX-TDA50 only)
Programming Manual References
2.7.1 [1-1] Slot
Feature Manual References
1.16.5 SVM (Simplified Voice Message)
SVM Cyclic Tone Option—Tone Off Maximum Time
Specifies the maximum time that the PBX waits for a cyclic tone to be sent from the telephone
company before recognizing it as a tone-off. When no tone is detected within the time set here, the
PBX recognizes it as a tone-off.
Note that this option can only be set when
SVM Cyclic Tone Detection
on this screen is set to
"Option".
To apply changes to this setting, follow the steps below:
1.
Change this setting.
A
B
C
A
D
B