2-Subscriber Level Configuration Parameters 

This section identifies the SIP service subscriber-specific parameters, including 
registration and authentication. These settings must be unique for each account. 
Provisioning a subscriber to register with Cbeyond allows calls to terminate to the 
subscriber’s line. Registration requires that a unique address of record (AoR) is 
provisioned on Cbeyond Application server cluster. A user name (SIP account) and a 
password (Authentication Password) will be provided from Cbeyond to each 
subscriber.  
 

 

Step 

Command 

Purpose 

Step 1 

Set SIP Account<compulsory>.

 

 

The register user ID must correspond 
with the line/port setting on Cbeyond 

Step 2 

Set Authentication ID 

<compulsory>. 

 

If the Authentication service is 
configured on Cbeyond, these 
parameters must be configured to 
match the Cbeyond settings.

 

Step 3 

Set Authentication Password 

<compulsory>. 

 

Specifies the password (compulsory). 

 

 

4- NAT Traversal

 

 
Based on your network architecture you need to choose the proper method to perform the NAT 
transversal. 
If you have chosen the fixed IP address method and the WAN port of your SIP-GW card is 
connected to the LAN side of your Broadband router, you have to Enable the NAT traversal and 
specify the Fixed IP address of the Broadband Router. 
 
Example ( SIP-GW WAN side IP address is Private IP address 192.168.10.100) and your SIP 
account is authenticated over the Cbeyond Circuit IP address, Fixed IP address NAT traversal 
has to be enabled 
 
If the Authentication IP address is over the Private IP address of the WAN side of the SIP-GW 
card, The NAT Traversal should be disabled. 
 

 
 
 
 
 

 
 

Summary of Contents for KX-TDA50

Page 1: ...7 17 2009 1 Revision 2 Cbeyond SIP Trunks Configuration Guide PBX Platform KX TDA50...

Page 2: ...additional DSP daughter card KX TDA5451 which provides additional 4 Channels The maximum numbers of SIP Gateway cards to be installed into one PBX is one card This guide describes the specific configu...

Page 3: ...2 Architecture Overview The following diagram illustrates simple VOIP networks connecting the SIP GW4 card The Case of Cbeyond Setup Cbeyond will provide its services over a dedicated Circuit terminat...

Page 4: ...Internet Explorer from the Start menu 2 Specify the URL of the SIP GW4 Maintenance Utility with the IP address http 192 168 0 1 8000 Exp 3 a The log in screen is displayed In the User name box type IN...

Page 5: ...5 0 WAN port IP address 192 168 0 2 Subnet mask 24 255 255 255 0 If you do so disconnect the cables from the LAN and WAN ports and reboot the SIP GW4 card Then connect the cable only to the LAN port a...

Page 6: ...et the TDA50 SIP server to the Fully Qualified Domain Name FQDN for the Cbeyond Application Server cluster The domain must match the domain configured for the Cbeyond subscriber s line port domain Ste...

Page 7: ...he port number is 1024 65535 2 No need to change unless necessary 3 The actual length of time depends on the negotiation with the SIP server or the other device Therefore the Registration Timer will n...

Page 8: ...ation ID compulsory If the Authentication service is configured on Cbeyond these parameters must be configured to match the Cbeyond settings Step 3 Set Authentication Password compulsory Specifies the...

Page 9: ...est as of 02 10 09 SIP GW card V 4 002 TDA50 MPR V 5 0003 Useful Hints 1 Update your system software once the update is available through the Dealer website to make use of added features and improved...

Reviews: