PROBLEM
PROBABLE CAUSE
SOLUTION
•
Originating an outside
call, call transfer, or
conference cannot be
performed.
•
The corresponding
flexible button does not
exist on the PT.
•
Programme the flexible button. Refer
to "1.20.2 Flexible Buttons" in the Feature
Guide.
•
The LED of the CS does
not change to Green ON.
•
CS is not connected
properly.
•
Make sure that the cable is connected
properly with correct pin assignments. Also,
make sure that the cable does not make
short circuits.
•
CS is not set for normal
operation.
•
Switch all DIP switches off.
•
The status of the port that
the CS is connected to is
Out of Service.
•
Change the port status from Out of Service
to In Service using the Maintenance
Console.
<KX-TDA0158 only>
•
The Local Processor
(LPR) software of the
corresponding DHLC/
DLC card is not version
5.000 or later.
•
Upgrade the LPR software of the DHLC/
DLC card.
<KX-TDA0158 only>
•
Both KX-TDA0158 and
KX-TDA0155 CSs are
connected to the same
card, and the
KX-TDA0158 CSs are
connected to
higher-numbered pins on
the card than the
KX-TDA0155 CSs.
•
Connect the KX-TDA0158 CSs to
lower-numbered pins on the card than the
KX-TDA0155 CSs.
•
Connect the KX-TDA0158 and
KX-TDA0155 CSs to different cards.
•
The LED of the CS stays
Red ON during normal
operation.
•
CS malfunction
•
Replace the CS.
•
"CLEAR SCAN DATA" is
displayed on the PS’s
screen after turning on
the PS.
•
The PS cannot be used
for normal operation
when scan data is stored
on the PS.
•
Clear the scan data (refer to "3.9.5 Site
Survey Using the KX-TCA255/
KX-TCA256/KX-TCA355/
KX-TD7590" or "3.11.5 Site Survey").
•
Cannot register the PS.
•
Wrong Personal
Identification Number
(PIN) is registered to the
PS.
•
Enter the PIN set to the PBX into the PS.
•
PS becomes out of
range.
•
CSIF card is not working.
•
Install the CSIF card properly.
278
Installation Manual
5.1.3 Operation
Summary of Contents for KX-TDE100
Page 40: ...40 Installation Manual 1 4 3 System Capacity ...
Page 48: ...48 Installation Manual 2 1 3 Activation Key File ...
Page 262: ...262 Installation Manual 3 16 1 Starting the PBX ...
Page 270: ...270 Installation Manual 4 3 1 Installing and Starting the Maintenance Console ...
Page 283: ...Section 6 Appendix Installation Manual 283 ...
Page 286: ...286 Installation Manual 6 1 2 PMMPR Software File Version 2 01xx ...
Page 287: ...Index Installation Manual 287 ...
Page 293: ...Installation Manual 293 Notes ...