background image

2.1  PT Programming

2.1.1  Programming Instructions

Required Telephone/Extension

PBX settings can be customized through system programming by using a proprietary telephone (PT) with a
multiline display, such as the KX-NT343 or KX-NT346. To access system programming, the Class of Service
(COS) assigned to the PT’s extension must be programmed to allow system programming, or the PT must be
connected to the lowest-numbered port on the card installed in the lowest-numbered slot.
Only one system programming session can be performed at a time. This means that only one user can access
system programming at a time, whether through a PT or PC.
For a list of characters that can be entered during system programming, see Section 1.1.3  Entering
Characters.

Buttons and Functions

Fixed Buttons

Function

KX-NT300/KX-DT300

KX-NT136/KX-T7600

KX-T7200/KX-T7400

*1

REDIAL

PREVIOUS

SP-PHONE

NEXT

FWD/DND

(Page up)

CONF

(Page down)

AUTO DIAL

STORE

ENTER

Back to Previous Menu

(CANCEL)

SHIFT

SHIFT

SHIFT

SHIFT

PAUSE

PAUSE

PROGRAM

PAUSE

PROGRAM

HOLD

HOLD

END

AUTO ANS

MUTE

MESSAGE

MUTE

AUTO ANSWER

MESSAGE

SELECT

14

PT Programming Manual

Document Version  2009-12  

2.1.1 Programming Instructions

Summary of Contents for KX-TDE100

Page 1: ...IP PBX Please read this manual carefully before using this product and save this manual for future use KX TDE100 KX TDE200 PMMPR Software File Version 3 0000 or later KX TDE600 PGMPR Software File Ve...

Page 2: ...References Found in the PT Programming Manual PT Programming Manual References Related sections of the PT Programming Manual are listed for your reference Feature Manual References The Feature Manual...

Page 3: ...ke has stopped and contact an authorized Panasonic Factory Service Center NOTES The contents of this manual apply to PBXs with a certain software version as indicated on the cover of this manual To co...

Page 4: ...or PT Programming 20 111 System Password for User for PT Programming 20 112 Manager Password 21 120 Verification Code 21 121 Verification Code Name 21 122 Verification Code Personal Identification Num...

Page 5: ...3 DID Destination 29 471 Host PBX Access Code 29 472 Extension to CO Line Call Duration 30 473 CO to CO Line Call Duration 30 475 DISA Silence Detection 30 476 DISA Continuous Signal Detection 30 477...

Page 6: ...al Identification Number PIN for PS Registration 39 699 CS Status Reference 39 2 1 10 Resource Interface Programming 40 700 External Pager Floating Extension Number 40 710 Music Source Selection for B...

Page 7: ...3 1 Revision History 46 3 1 1 KX TDE100 KX TDE200 PMMPR Software File Version 3 0xxx 46 3 1 2 KX TDE600 PGMPR Software File Version 3 0xxx 46 3 2 Feature Programming References 47 Document Version 20...

Page 8: ...8 PT Programming Manual Document Version 2009 12 Table of Contents...

Page 9: ...Section 1 Overview This section provides an overview of programming the PBX Document Version 2009 12 PT Programming Manual 9...

Page 10: ...g functions of the PBX By giving different users access to different passwords it is possible to control the amount of programming that each user is able to perform The following types of system passw...

Page 11: ...nformation on how to back up the system data refer to the on line help of the Maintenance Console However as system passwords can be extracted from backup copies of the system data file do not allow u...

Page 12: ...ing two or more characters that use the same button consecutively e g G and I you must press this button or the FWD DND button after entering the first character If SELECT is pressed the characters fo...

Page 13: ...Section 2 PT Programming This section serves as reference operating instructions when using a display PT to program the PBX Document Version 2009 12 PT Programming Manual 13...

Page 14: ...ystem programming session can be performed at a time This means that only one user can access system programming at a time whether through a PT or PC For a list of characters that can be entered durin...

Page 15: ...istrator Level Allows the programming of all settings accessible through PT programming PROGRAM PAUSE 1234 System Password for Administrator Programming No 3 digits for PT Programming User Level Allow...

Page 16: ...ally removing it 2 1 2 Maximum Values Throughout this manual maximum entry values are shown for each programming item as shown in the example below These values vary by PBX model Disable Enable SELECT...

Page 17: ...34 1 72x LCOT8 KX TDE100 KX TDE200 only 01 08 400 409 41x 450 LCOT16 KX TDE100 KX TDE200 only 01 16 ELCOT16 KX TDE600 only 01 16 Enter values as two digit numbers e g 04 for port 4 1 Enter card numbe...

Page 18: ...sion number is to be programmed modified quit the application first 004 Extension Name 004 Name Max 20 characters END Extn No ENTER ENTER 1 5 digits 005 Extension Personal Identification Number PIN 00...

Page 19: ...Device Assignment Note that if one or more SDN buttons have been set at the DSS Console they must be deleted before this setting can be changed 008 Absent Message 008 1 8 Location No END Message ENTE...

Page 20: ...y No AM PM SELECT 103 Idle Line Access Local Access 103 Location No Trunk Group No END ENTER ENTER Location No Trunk Group No KX TDE100 01 64 KX TDE200 01 64 KX TDE600 01 96 KX TDE100 01 64 KX TDE200...

Page 21: ...k that fraudulent telephone calls will be made if a third party discovers a personal identification number PIN verification code PIN or extension PIN of the PBX The cost of such calls will be billed t...

Page 22: ...201 Transfer Recall Time 201 END ENTER ENTER 1 240 s Time 60 s 203 Intercept Time 203 END ENTER ENTER 1 240 s Time 40 s 1 Day 2 Lunch 3 Break 4 Night Time No Time No 204 Hot Line Waiting Time 204 0 1...

Page 23: ...ENTER 210 DISA CO to CO Line Call Prolong Time 210 0 7 min Time END ENTER ENTER 3 min 211 DISA Intercept Time 211 0 60 s Time END ENTER ENTER 40 s 1 Day 2 Lunch 3 Break 4 Night Time No Time No 2 1 6 T...

Page 24: ...R 303 Special Carrier Access Code 303 Max 16 digits Carrier Access Code Location No END ENTER ENTER KX TDE100 01 20 KX TDE200 01 20 KX TDE600 001 100 304 Emergency Number 304 Max 32 digits Emergency N...

Page 25: ...3 TimeC 4 TimeD ARS Time No ENTER ENTER 330 AM PM SELECT KX TDE100 01 16 KX TDE200 01 16 KX TDE600 01 48 331 346 ARS Routing Plan Table 1 16 KX TDE100 KX TDE200 only 331 346 Day No Carrier Table No 1...

Page 26: ...Carrier Table No Trunk Group No END ENTER ENTER SELECT Disable Enable KX TDE100 01 10 KX TDE200 01 10 KX TDE600 01 48 KX TDE100 01 64 KX TDE200 01 64 KX TDE600 01 96 352 ARS Removed Number of Digits...

Page 27: ...characters Name END ENTER ENTER 3 digits CO Line No 402 LCOT Trunk Group Number 402 3 digits Trunk Group No END ENTER ENTER Trunk No KX TDE100 01 64 KX TDE200 01 64 KX TDE600 01 96 01 409 LCOT CO Line...

Page 28: ...ER ENTER Slot No Port No Mode No 051 400 ms 414 LCOT CPC Signal Detection Time Incoming 414 END ENTER ENTER 0 None 1 6 5 2 113 N 1 8 ms Slot No Port No Mode No 051 400 ms 416 LCOT Pause Time 416 1 5 2...

Page 29: ...its DID No END ENTER ENTER 452 DID Name 452 0001 1000 Location No Max 20 characters Name END ENTER ENTER 453 DID Destination 453 0001 1000 Location No Destination No END ENTER ENTER 1 Day 2 Lunch 3 Br...

Page 30: ...No No Detect Detect END SELECT KX TDE100 01 64 KX TDE200 01 64 KX TDE600 01 96 476 DISA Continuous Signal Detection 476 Trunk Group No No Detect Detect END SELECT ENTER ENTER KX TDE100 01 64 KX TDE20...

Page 31: ...200 01 64 KX TDE600 01 96 501 TRS Level 501 01 64 COS No Time No 1 7 Level END ENTER ENTER 1 Day 2 Lunch 3 Break 4 Night 1 502 CO Line Call Duration Limitation 502 01 64 COS No END Disable Enable SELE...

Page 32: ...ENTER 508 Account Code Mode 508 01 64 COS No END Option Forced SELECT ENTER ENTER 509 TRS Level for System Speed Dialing 509 01 64 COS No 1 7 TRS Level END ENTER ENTER 1 510 TRS Level for Extension Di...

Page 33: ...le 515 01 64 COS No END ENTER ENTER 516 Programming Mode Limitation 516 01 64 COS No END SELECT ENTER ENTER Disable Personal System Personal COS No 01 63 Personal COS No 64 System Personal 2 1 9 Exten...

Page 34: ...ne all SDN buttons customized for that device will be deleted 602 Class of Service 602 01 64 1 5 digits 01 COS No END ENTER ENTER Extn No 603 Extension User Group 603 Extn User Group No END ENTER ENTE...

Page 35: ...ng 621 Location No END Immediate 1 6 rings No ring SELECT ENTER ENTER Incoming Call Distribution Group No 001 128 KX TDE100 01 32 KX TDE200 01 32 KX TDE600 001 128 622 Incoming Call Distribution Group...

Page 36: ...Distribution Group No 001 128 626 Overflow Time 626 Overflow Time END ENTER ENTER Incoming Call Distribution Group No 001 128 None 1 125 10 s 627 Destination When All Busy 627 Max 32 digits Destinati...

Page 37: ...N OGM N SELECT ENTER ENTER KX TDE100 01 64 KX TDE200 01 64 KX TDE600 001 128 632 Maximum Number of Agents 632 No Limitation 01 32 Number of Agents END ENTER ENTER Incoming Call Distribution Group No 0...

Page 38: ...32 KX TDE600 001 096 KX TDE100 KX TDE200 Pickup Group No 01 32 Extn User Group No 001 032 Pickup Group No 33 64 All extension user groups KX TDE600 Pickup Group No Extn User Group No 660 VM Group Floa...

Page 39: ...TDE100 001 128 KX TDE200 001 128 KX TDE600 001 512 Note For details about PS registration refer to the Quick Installation Guide for the relevant Cell Station CS 691 PS Termination 691 PS No END ENTER...

Page 40: ...END External Internal1 Internal2 ENTER ENTER SELECT AUTO ANS MESSAGE 711 Music on Hold 711 END Tone BGM1 8 Music Source No ENTER ENTER 712 Music for Transfer 712 END Hold Music Ring back SELECT ENTER...

Page 41: ...D Message No Max 20 characters Name ENTER ENTER 01 64 732 DISA Security Mode 732 END None CO Line All SELECT ENTER ENTER 2 1 11 SMDR Maintenance Programming 800 RS 232C Parameter New Line Code 800 END...

Page 42: ...800 END 1 bit 2 bits SELECT 5 Location ENTER ENTER 801 External Modem Control 801 END ENTER ENTER Command No 1 5 802 SMDR Page Length 802 END 4 99 lines 66 Page length ENTER ENTER 803 SMDR Skip Perfor...

Page 43: ...igits 812 ISDN Remote Floating Extension Number 812 END ENTER ENTER Extn No 1 5 digits 2 1 12 Card Programming 900 Slot Card Type Reference 900 Reference only Slot No Card Name END HOLD ENTER 901 Slot...

Page 44: ...n 910 OPB3 Option Card Type Reference 910 END Slot No Reference only Option Card Type ENTER 1 3 Card No 911 OPB3 Option Card Deletion 911 END Slot No 1 3 Card No Delete ENTER ENTER Confirming the dele...

Page 45: ...Section 3 Appendix Document Version 2009 12 PT Programming Manual 45...

Page 46: ...rogramming 710 Music Source Selection for BGM2 711 Music on Hold 3 1 2 KX TDE600 PGMPR Software File Version 3 0xxx Changed Contents 2 1 9 Extension Programming 690 PS Registration 2 1 10 Resource Int...

Page 47: ...uting Plan Time Table 331 346 ARS Routing Plan Table 1 16 KX TDE100 KX TDE200 only 350 ARS Carrier Name 351 ARS Trunk Group for Carrier Access 352 ARS Removed Number of Digits for Carrier Access 353 A...

Page 48: ...Name Feature Manual References 3 1 14 CLI Calling Line Identification Distribution CLIP Calling Line Identification Presentation 003 Extension Number 606 CLIP Number Feature Manual References 3 1 15...

Page 49: ...O Line Call Duration 502 CO Line Call Duration Limitation Feature Manual References 3 1 17 CO Line Call Limitation Dial Mode Selection 410 LCOT Dialing Mode 411 LCOT Pulse Rate 412 LCOT DTMF Minimum D...

Page 50: ...ing Message OGM Name 732 DISA Security Mode Feature Manual References 4 1 8 DISA Direct Inward System Access DND Do Not Disturb 507 DND Override Feature Manual References 4 1 10 DND Do Not Disturb Doo...

Page 51: ...nsion Dial Lock Feature Manual References 5 1 4 Extension Dial Lock Extension PIN Personal Identification Number 005 Extension Personal Identification Number PIN Feature Manual References 5 1 6 Extens...

Page 52: ...Number 812 ISDN Remote Floating Extension Number Feature Manual References 6 1 5 Floating Extension FWD Call Forwarding 472 Extension to CO Line Call Duration 473 CO to CO Line Call Duration 504 Call...

Page 53: ...up Features Group Call Distribution 621 Incoming Call Distribution Group Delayed Ringing 624 Incoming Call Distribution Group Distribution Method 632 Maximum Number of Agents Feature Manual References...

Page 54: ...ing 680 Idle Extension Hunting Type 681 Idle Extension Hunting Group Member Feature Manual References 9 1 9 Idle Extension Hunting Intercept Routing 203 Intercept Time 604 Extension Intercept Destinat...

Page 55: ...c on Hold 710 Music Source Selection for BGM2 711 Music on Hold Feature Manual References 11 1 4 Music on Hold OGM Outgoing Message 631 Sequences in Queuing Time Table 730 Outgoing Message OGM Floatin...

Page 56: ...References 13 1 5 PC Console PC Phone Private Network Features 453 DID Destination 500 Trunk Group Number Feature Manual References 13 1 15 PRIVATE NETWORK FEATURES Private Network Features NDSS Netw...

Page 57: ...ures QSIG CLIP COLP Calling Connected Line Identification Presentation and CNIP CONP Calling Connected Name Identification Presentation PS Connection 690 PS Registration 691 PS Termination 692 Persona...

Page 58: ...Stop Bit Length 802 SMDR Page Length 803 SMDR Skip Perforation 804 SMDR Outgoing Call Printing 805 SMDR Incoming Call Printing Feature Manual References 16 1 3 SMDR Station Message Detail Recording S...

Page 59: ...e Service Starting Time 514 Time Service Manual Switching Feature Manual References 17 1 5 Time Service TRS Toll Restriction 300 TRS Override by System Speed Dialing 301 TRS Denied Code 302 TRS Except...

Page 60: ...evice Assignment 660 VM Group Floating Extension Number Feature Manual References 19 1 3 Voice Mail VM Group Voice Mail DPT Digital Integration 201 Transfer Recall Time Feature Manual References 19 1...

Page 61: ...Parallel Mode 515 Wireless XDP Parallel Mode for Paired Telephone Feature Manual References 20 1 5 Wireless XDP Parallel Mode Document Version 2009 12 PT Programming Manual 61 3 2 Feature Programming...

Page 62: ...material is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasoni...

Reviews: