Pin Assignments
Amphenol Connector
No.
Signal Name
Function
No.
Signal
Name
Function
50 25
26 1
1
RA
Ring port 1
26
TA
Tip port 1
2
RB
Ring port 2
27
TB
Tip port 2
3
RC
Ring port 3
28
TC
Tip port 3
4
RD
Ring port 4
29
TD
Tip port 4
5
RE
Ring port 5
30
TE
Tip port 5
6
RF
Ring port 6
31
TF
Tip port 6
7
RG
Ring port 7
32
TG
Tip port 7
8
RH
Ring port 8
33
TH
Tip port 8
9
RI
Ring port 9
34
TI
Tip port 9
10
RJ
Ring port 10
35
TJ
Tip port 10
11
RK
Ring port 11
36
TK
Tip port 11
12
RL
Ring port 12
37
TL
Tip port 12
13
RM
Ring port 13
38
TM
Tip port 13
14
RN
Ring port 14
39
TN
Tip port 14
15
RO
Ring port 15
40
TO
Tip port 15
16
RP
Ring port 16
41
TP
Tip port 16
17-25
Reserved
–
42-50
Reserved
–
LED Indications
Indication
Colour
Description
CARD STATUS
Green/Red
Card status indication
•
OFF: Power Off
•
Green ON: Normal (all ports are idle)
•
Green Flashing (60 times per minute): Normal (a port is in use)
•
Red ON: Fault (includes reset)
•
Red Flashing (60 times per minute): Out of Service
130
Installation Manual
3.6.7 SLC16 Card (KX-TDA0174), MSLC16 Card (KX-TDA0175), and CSLC16 Card (KX-TDA0177)
Summary of Contents for KX-TDE200
Page 20: ...20 Installation Manual Table of Contents...
Page 172: ...172 Installation Manual 3 13 1 Starting the PBX...
Page 192: ...192 Installation Manual 5 1 5 Troubleshooting by Error Log...
Page 193: ...Section 6 Appendix Installation Manual 193...
Page 197: ...Index Installation Manual 197...
Page 203: ...Installation Manual 203 Notes...