Value Range
Disable, Enable
Register Sending Interval
Specifies the maximum length of interval time after which the PBX sends the REGISTER message.
Default
3600 s
Value Range
10–86400 s
Un-Register Ability when port INS
Specifies whether to unregister the previous registration and send the REGISTER message to the SIP server
when the port status is set back to INS.
Default
Enable
Value Range
Disable, Enable
Registrar Server—Name
Specifies the domain name of the SIP registrar server.
Default
Not stored.
Value Range
Max. 100 characters
Registrar Server—IP Address
Specifies the IP address of the SIP registrar server. This setting is compulsory when a register IP address is
provided.
Default
Not stored.
Value Range
1.0.0.0–223.255.255.255
Registrar Server Port Number
Specifies the port number of the SIP registrar server.
Default
5060
24
Programming Manual for Virtual SIP CO Line Card