46
KX-TG1032SK/KX-TGA101S
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide
(P.24)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in
Check Point (Base Unit)
(P.37).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PQZZTG1032M
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.2.1. Connections
Connect the AC adaptor to CN2 (base unit).
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Summary of Contents for KX-TG1032SK
Page 2: ...2 KX TG1032SK KX TGA101S ...
Page 14: ...14 KX TG1032SK KX TGA101S 4 6 Signal Route ...
Page 15: ...15 KX TG1032SK KX TGA101S ...
Page 17: ...17 KX TG1032SK KX TGA101S 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 19: ...19 KX TG1032SK KX TGA101S 8 1 2 Handset ...
Page 33: ...33 KX TG1032SK KX TGA101S 9 1 4 5 RF BBIC Interface Signal Wave Form SYCL SYEN SYDA ...
Page 39: ...39 KX TG1032SK KX TGA101S ...
Page 40: ...40 KX TG1032SK KX TGA101S 10 1 2 Handset ...
Page 41: ...41 KX TG1032SK KX TGA101S 10 1 3 Charger Unit ...
Page 42: ...42 KX TG1032SK KX TGA101S ...
Page 43: ...43 KX TG1032SK KX TGA101S 10 2 How to Replace the Handset LCD ...
Page 44: ...44 KX TG1032SK KX TGA101S 10 3 How and Where to fix the spacer ...
Page 45: ...45 KX TG1032SK KX TGA101S ...
Page 65: ...65 KX TG1032SK KX TGA101S Memo ...
Page 72: ...72 KX TG1032SK KX TGA101S Memo ...
Page 78: ...78 KX TG1032SK KX TGA101S 15 3 Cabinet and Electric Parts Charger Unit ...