12.7.3. Check Table for RF part
No.
Item
BU checking
HS checking
1a Link confirmation Normal
1.
Re-resister HS Regular Unit (working) to BU.
2.
Press [Talk] key of the HS Regular Unit to
establish link.
1.
Re-resister HS to BU of Regular Unit (working).
2.
Press [Talk] key of the HS to establish link.
1b Link confirmation TX Test 1.
Re-resister HS Regular Unit (working) to BU.
2.
Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: High)
3.
Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: Low)
4.
Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5.
Press [1] key of HS Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of HS Regular
Unit is more than "e0 (hex)".
1.
Re-resister HS to BU Regular Unit (working).
2.
Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: Low)
3.
Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: High)
4.
Press [1] key of HS to establish link about 5m
away from BU of Regular Unit.
5.
Press [1] key of BU Regular Unit to set RSSI
mode, and press [2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of BU Regular
Unit is more than "e0 (hex)".
1c Link confirmation RX Test 1.
Re-resister HS Regular Unit (working) to BU.
2.
Set BU to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: Low)
3.
Set HS Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: High)
4.
Press [1] key of HS Regular Unit to establish link
about 5m away from BU.
5.
Press [1] key of BU to set RSSI mode, and press
[2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of BU is more
than "e0(hex)".
1.
Re-resister HS to BU of Regular Unit (working).
2.
Set BU Regular Unit to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: High)
3.
Set HS to TEST Link mode. (*1)
(CH:45ch / TX Power: High / RX Gain: Low)
4.
Press [1] key of HS to establish link about 5m
away from BU Regular Unit.
5.
Press [1] key of HS to set RSSI mode, and press
[2] key to set RX Gain Low.
6.
Confirm the value of RSSI in LCD of HS is more
than "e0(hex)".
2
Control signal confirmation 1.
Set TX Burst mode.(*1)
2.
Check DSP interface.(*2)
1.
Set TX Burst mode.(*1)
2.
Check DSP interface.(*2)
3
X’tal Frequency
confirmation
1.
Adjust X’tal mode.(*1)
2.
Check X´tal Frequency.
(13.824000MHz±100Hz)
1.
Adjust X’tal mode.(*1)
2.
Check X´tal Frequency.
(13.824000MHz±100Hz)
4
TX Power confirmation
1.
Set BU to TX Burst mode at 45ch. (*1)
(TX Power: High)
2.
Set HS Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3.
Place HS Regular Unit about 5m away from BU.
4.
Confirm RSSI of HS Regular Unit is more than
1.75V by Oscilloscope.(*4)
1.
Set HS to TX Burst mode at 45ch. (*1)
(TX Power: High)
2.
Set BU Regular Unit to RX-CW TEST mode at
45ch (RX Gain is fixed Low Gain). (*1)
3.
Place HS about 5m away from BU Regular Unit.
4.
Confirm RSSI of BU Regular Unit is more than
1.75V by Oscilloscope.(*3)
5
RX Sensitivity confirmation 1.
Set BU to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2.
Set HS Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power: High)
3.
Place HS Regular Unit about 5m away from BU.
4.
Confirm RSSI of BU is more than 1.75V by
Oscilloscope.(*3)
1.
Set HS to RX-CW TEST mode at 45ch (RX Gain
is fixed Low Gain). (*1)
2.
Set BU Regular Unit to TX Burst mode at 45ch.
(*1) (TX Power: High)
3.
Place HS about 5m away from BU Regular Unit.
4.
Confirm RSSI of HS is more than 1.75V by
Oscilloscope.(*4)
Note:
(*1)
TEST MODE
(P.46)
(*2)
RF-DSP interface signal wave form
(P.44)
(*3)
CIRCUIT BOARD (Base Unit) Component View
(P.97)
(*4)
CIRCUIT BOARD (Handset) Component View
(P.99)
43
KX-TG2340JXS / KX-TGA236JXS
Summary of Contents for KX-TG2340JXS
Page 8: ...4 1 4 Battery Information 4 2 Battery Replacement 8 KX TG2340JXS KX TGA236JXS ...
Page 9: ...5 LOCATION OF CONTROLS 5 1 Base unit 9 KX TG2340JXS KX TGA236JXS ...
Page 10: ...5 2 Handset 10 KX TG2340JXS KX TGA236JXS ...
Page 12: ...7 SETTINGS 7 1 Connections 12 KX TG2340JXS KX TGA236JXS ...
Page 13: ...7 2 Connecting an Optional Headset 13 KX TG2340JXS KX TGA236JXS ...
Page 14: ...7 3 Function Menu Table Cross Reference Direct Commands P 19 14 KX TG2340JXS KX TGA236JXS ...
Page 15: ...7 4 Date and Time 15 KX TG2340JXS KX TGA236JXS ...
Page 16: ...7 5 Dialing Mode 7 6 Line Mode 16 KX TG2340JXS KX TGA236JXS ...
Page 17: ...7 7 Voice Enhancer Technology 7 8 Ringer Tone 17 KX TG2340JXS KX TGA236JXS ...
Page 18: ...18 KX TG2340JXS KX TGA236JXS ...
Page 19: ...7 9 Direct Commands 19 KX TG2340JXS KX TGA236JXS ...
Page 20: ...8 1 Answering Calls 8 OPERATION 20 KX TG2340JXS KX TGA236JXS ...
Page 21: ...8 2 For Call Waiting Service Users 8 3 Using the PAUSE Key 21 KX TG2340JXS KX TGA236JXS ...
Page 22: ...8 4 Dial Lock 22 KX TG2340JXS KX TGA236JXS ...
Page 24: ...8 5 FLASH Button 24 KX TG2340JXS KX TGA236JXS ...
Page 25: ...8 6 Phone Book 8 6 1 Storing Names and Numbers 25 KX TG2340JXS KX TGA236JXS ...
Page 26: ...26 KX TG2340JXS KX TGA236JXS ...
Page 27: ...8 6 2 Dialing from the Phone Book 27 KX TG2340JXS KX TGA236JXS ...
Page 28: ...8 6 3 Chain Dial 28 KX TG2340JXS KX TGA236JXS ...
Page 31: ...31 KX TG2340JXS KX TGA236JXS ...
Page 35: ...11 ASSEMBLY INSTRUCTIONS 11 1 Fix the LCD to P C Board Handset 35 KX TG2340JXS KX TGA236JXS ...
Page 39: ...Note DSP is IC501 12 5 Check Battery Charge 39 KX TG2340JXS KX TGA236JXS ...
Page 44: ...12 7 4 RF DSP interface signal wave form 44 KX TG2340JXS KX TGA236JXS ...
Page 47: ...13 1 2 RX CW TEST Mode 47 KX TG2340JXS KX TGA236JXS ...
Page 48: ...13 1 3 Test Link Mode 48 KX TG2340JXS KX TGA236JXS ...
Page 49: ...13 2 Test Mode Flow Chart for Handset 13 2 1 TX Burst Mode 49 KX TG2340JXS KX TGA236JXS ...
Page 50: ...13 2 2 RX CW TEST Mode 50 KX TG2340JXS KX TGA236JXS ...
Page 76: ...20 SIGNAL ROUTE Each signal route is as follows 76 KX TG2340JXS KX TGA236JXS ...
Page 79: ...23 EXPLANATION OF IC TERMINALS RF Unit 23 1 IC901 79 KX TG2340JXS KX TGA236JXS ...
Page 82: ...25 CABINET AND ELECTRICAL PARTS Base Unit 82 KX TG2340JXS KX TGA236JXS ...
Page 83: ...26 CABINET AND ELECTRICAL PARTS Handset 83 KX TG2340JXS KX TGA236JXS ...
Page 84: ...27 ACCESSORIES AND PACKING MATERIALS 84 KX TG2340JXS KX TGA236JXS ...
Page 101: ...101 KX TG2340JXS KX TGA236JXS M T N KXTG2340JXS KXTGA236JXS ...