83
KX-TG6700BXB/KX-TGA670BXB
12 Measurements and Adjustments
12.1. Things to Do after Replacing IC
12.1.1. X501 (Base Unit), X201 (Handset) Check
Equipment: Frequency counter
Check Point for measurement: BCK
Checking tolerance: 13.824 MHz ± 270 Hz (Base Unit)/13.824 MHz ± 100 Hz (Handset)
12.1.1.1. Check and Adjust X501 (Base Unit) Frequency
1. Set up Base Unit in TEST mode.
2. Press following keys in order to Adjust Crystal mode. [INTERCOM], [INTERCOM], [INTERCOM], [1], [4]. Check BCK
frequency.
3. If the BCK frequency is out of the checking tolerance (± 270 Hz), adjust to Adjustment tolelance (± 30 Hz) by pressing [ ] or
[ ] key.
Adjustment Tolerance: 13.824 MHz ± 30 Hz
4. Press [INTERCOM] key to write the new frequency factor in Memory.
5. Turn the power off. Then this value is available.
Cross Reference:
12.1.1.2. Check and Adjust X201 (Handset) Frequency
1. Set DC power supply to 2.6 V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key to Adjust Crystal mode (
“
Clock Adj.
”
is displayed on LCD). Check BCK frequency.
4. If the BCK frequency is out of the checking tolerance (± 100 Hz), adjust to Adjustment tolelance (± 30 Hz) by pressing [ ] or
[ ] key.
Adjustment Tolerance: 13.824 MHz ± 30 Hz
5. Press [TALK] key to write the new frequency factor in EEPROM.
6. Turn the power off. Then this value is available.
Cross Reference:
12.1.2. Adjust Battery Low Detector Voltage (Handset)
After Handset’s DSP (IC201) or EEPROM (IC241) replacement, Re-writing Battery Low voltage to EEPROM is required.
With following Handset Adjustment Flow, adjust DC power supply and DC voltmeter by the procedure below.
1. Set DC power supply to 2.6 V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key and [OFF] key to Adjust Batt Low mode. (“Bat Adj.” is displayed on LCD)
4. Change the voltage of the DC power supply to 2.34 V accurately. Check the voltage at P.C. board pads because some voltage
drops occur due to the usage of long or thin cables.
5. Press [TALK] key twice to write voltage value in EEPROM.
6. Press [TALK] key twice to write charge value 1 in EEPROM.
7. Change the voltage of the DC power supply to 2.90 V accurately.
8. Press [TALK] key twice to write charge value 2 in EEPROM.
9. Turn the power off. Then this value is available.
Note:
Refer to
(P.85) for connection of DC power supply and voltmeter.
Cross Reference:
Summary of Contents for KX-TG6700BXB
Page 2: ...2 KX TG6700BXB KX TGA670BXB ...
Page 6: ...6 KX TG6700BXB KX TGA670BXB 3 Specifications ...
Page 35: ...35 KX TG6700BXB KX TGA670BXB 4 11 Signal Route Each signal route is as follows ...
Page 36: ...36 KX TG6700BXB KX TGA670BXB RF part signal route ...
Page 40: ...40 KX TG6700BXB KX TGA670BXB 6 1 2 Connecting the Telephone Line Cord ...
Page 41: ...41 KX TG6700BXB KX TGA670BXB 6 1 2 1 If you subscribe to a DSL service ...
Page 43: ...43 KX TG6700BXB KX TGA670BXB 6 4 1 Battery Level 6 4 2 Panasonic Battery Performance ...
Page 46: ...46 KX TG6700BXB KX TGA670BXB ...
Page 47: ...47 KX TG6700BXB KX TGA670BXB 7 2 2 Programming Using the Direct Commands ...
Page 48: ...48 KX TG6700BXB KX TGA670BXB ...
Page 49: ...49 KX TG6700BXB KX TGA670BXB 7 3 Error Messages ...
Page 50: ...50 KX TG6700BXB KX TGA670BXB 7 4 Troubleshooting ...
Page 51: ...51 KX TG6700BXB KX TGA670BXB ...
Page 52: ...52 KX TG6700BXB KX TGA670BXB ...
Page 72: ...72 KX TG6700BXB KX TGA670BXB 10 1 9 5 RF DSP Interface Signal Wave Form Test Burst Mode ...
Page 73: ...73 KX TG6700BXB KX TGA670BXB Test Burst Mode ...
Page 80: ...80 KX TG6700BXB KX TGA670BXB 11 1 2 Handset ...
Page 81: ...81 KX TG6700BXB KX TGA670BXB 11 1 3 Charger Unit ...
Page 93: ...93 KX TG6700BXB KX TGA670BXB Memo ...
Page 97: ...97 KX TG6700BXB KX TGA670BXB Memo ...
Page 106: ...106 KX TG6700BXB KX TGA670BXB Memo ...
Page 116: ...116 KX TG6700BXB KX TGA670BXB 15 3 Explanation of IC Terminals RF Part 15 3 1 IC701 ...
Page 117: ...117 KX TG6700BXB KX TGA670BXB 15 3 2 IC801 Backside Terminal GND ...
Page 118: ...118 KX TG6700BXB KX TGA670BXB 15 3 3 IC851 Backside Terminal GND ...
Page 122: ...122 KX TG6700BXB KX TGA670BXB 16 3 Cabinet and Electrical Parts Charger Unit ...
Page 123: ...123 KX TG6700BXB KX TGA670BXB 16 4 Accessories and Packing Materials 16 4 1 KX TG6700BXB ...
Page 124: ...124 KX TG6700BXB KX TGA670BXB 16 4 2 KX TGA670BXB ...