Parallel Connection Detect Circuit/Auto Disconnect Circuit
Function:
In order to disable call waiting and stutter tone functions when using telephones connected in parallel, it is necessary to have a
circuit that judges whether a telephone connected in parallel is in use or not. This circuit determines whether the telephone
connected in parallel is on hook or off hook by detecting changes in the T/R voltage.
Circuit Operation:
Parallel connection detection when on hook:
When on hook, the voltage is monitored at pin 17 of IC501. There is no parallel connection if the voltage is
0.54 V or higher, while a parallel connection is deemed to exist if the voltage is lower.
Parallel connection detection when off hook:
When off hook, the voltage is monitored at pin 18 of IC501; the presence/absence of a parallel connection is determined by
detecting the voltage changes.
If the Auto disconnect function is ON and statuses are Hold, receiving ICM, OGM transmitting, BBIC disconnects the line after
detecting parallel connection is off hook.
Summary of Contents for KX-TGA403LAT
Page 2: ...2 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT ...
Page 23: ...23 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT 4 9 Signal Route ...
Page 24: ...24 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT RF part signal route ...
Page 28: ...28 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT 8 1 2 Handset ...
Page 44: ...44 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT ...
Page 45: ...45 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT 11 1 2 Handset ...
Page 46: ...46 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT 11 1 3 Charger Unit ...
Page 65: ...65 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT Memo ...
Page 69: ...69 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT Memo ...
Page 76: ...76 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT Memo ...
Page 83: ...83 KX TG4021LAT KX TG4022LAT KX TG4023LAT KX TGA403LAT 16 4 Accessories A2 A3 A1 ...