42
KX-TGC210/KX-TGC212/KX-TGC213/KX-TGC220/KX-TGC222/KX-TGCA20
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
The Setting Method of JIG (Handset)
(P.54) is required beforehand.
The connections of adjustment equipment are as shown in
Symptom
Remedy (*2)
You don’t have DECT Tester.
You have DECT Tester.
(Model Number: CMD60)
Battery strength is not indicated correctly by Battery icon.
Check item (A) - (D), (E) - (G).
Check item (A) - (D), (E) - (G).
You cannot hear the caller’s voice.
Check item (A) - (C), (H), (N).
Check item (A) - (C), (H - (L)) - (N).
You cannot use handset little away from base unit even if the
handset is within range of the base unit.
-
Check item (I) - (M).
the Audio level is high or low.
Check item (N).
Check item (N).
The SP-Phone level is high or low.
Check item (O).
Check item (O).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)* 1.8 V Supply Adjustment
1.8V
1. Confirm that the voltage between test point 1.8V and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of 1.8V executing command “VDD XX“(XX is the
value).
IC1, Q1, C44,
R45, C40, C45
(
B
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1, R61
(
C
)* EEP-ROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned Value. (Value for reference is written at "EEPROM C/
SUM” in Software_Version_Table.xls).
IC1, IC3, RA5,
C69
(
D
) Charge Control Check &
Charge Current Monitor
Check
-
1. Apply 5.0 V between CHG(+) and CHG(-) with DC power supply and set
current limit to 150 mA.
Confirm the indication of “charging” on LCD.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
Confirm it after waiting over 1 minute at least.
(If charge control cannot be confirmed by this procedure, please use battery to
handset power supply and try again.)
IC1, Q4 Q9,
Q2, Q3, R2,
R7, R8, R6,
R9, C19, R45
(
E
)* Charge Detection (OFF)
Check
-
1. Stop supplying 5.0 V to CHG (+) and CHG (-).
2. Confirm the indication of “charging” has been cleared.
IC1, Q4 Q9,
Q2, Q3, R2,
R7, R8, R6,
R9, C19, R45
checksum value
program number
ex.)
73C7
DE92EN
Destination
BL,CX,HK,TU,BX,UE,ML
7258
DE92TA
TW
Summary of Contents for KX-TGCA20EX
Page 66: ...66 KX TGC210 KX TGC212 KX TGC213 KX TGC220 KX TGC222 KX TGCA20 Memo ...
Page 73: ...73 KX TGC210 KX TGC212 KX TGC213 KX TGC220 KX TGC222 KX TGCA20 Memo ...
Page 76: ...76 KX TGC210 KX TGC212 KX TGC213 KX TGC220 KX TGC222 KX TGCA20 Memo ...
Page 80: ...80 KX TGC210 KX TGC212 KX TGC213 KX TGC220 KX TGC222 KX TGCA20 Memo ...