Environmental Requirements (KX-TVA200 only)
The hard disk drive is sensitive to cold, heat, dryness, humidity, shock, vibration, and magnetic fields. Please
observe the conditions specified below.
Hard Disk Drive Usage Environment
Operating Temperature:
5 °C to 40 °C (41 °F to 104 °F)
Operating Humidity:
See the graph below.
Shock:
Under 5 G
Vibration:
5 Hz to 22 Hz:
0.0042 cm (0.020 in.) displacement; double amplitude, 1
octave per minute.
23 Hz to 350 Hz: Under 0.5 G
Magnetic Field:
DC: 0.6 mT
to 700 kHz: 0.7 µT
700 kHz to 1.5 MHz: 3 µT
Allowable Relative Humidity vs. Temperature
0
10
20
30
40
50
60
70
80
90
100
55
15
35
45
25
5
(°C)
Relative Humidity (%)
Temperature
Operating Area
41
59
77
95
113 131 (°F)