Description
Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
Value Range
00:00–23:59
Note
•
If the value for this setting is any valid value other than an empty
string, the unit downloads the configuration files at the fixed
time, and the settings specified in "
CFG_CYCLIC
",
"
CFG_CYCLIC_INTVL
", and "
CFG_RTRY_INTVL
" are
disabled.
•
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Default Value
Empty string
CFG_RESYNC_FROM_SIP
Value Format
String
Description
Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range
Max. 15 characters
Note
•
An empty string is not allowed.
Default Value
check-sync
Web User Interface Reference
Header Value for Resync Event (Page 163)
USR_PROV_SVR_URL
Value Format
String
Description
Specifies the Provisioning Server URL.
Note
•
The format of the IP address must be in dotted-decimal
notation, FQDN, or URL, as follows:
"<scheme>://<user>:<password>@<host>:<port>/<url-path>"
•
If "{mac}" is included in this URL, it will be replaced with the
unit’s MAC address in lower-case.
•
If "{MAC}" is included in this URL, it will be replaced with the
unit’s MAC address in upper-case.
•
If "{MODEL}" is included in this URL, it will be replaced with the
unit’s model name.
•
If "{fwver}" is included in this URL, it will be replaced with the
unit’s firmware version.
Value Range
Max. 1024 characters
Document Version 2014-04
Administrator Guide
217
5.3.6 Provisioning Settings
Summary of Contents for KX-UTG200
Page 188: ...188 Administrator Guide Document Version 2014 04 4 9 4 Sniffer Dump...
Page 284: ...284 Administrator Guide Document Version 2014 04 5 8 SSH Settings...
Page 302: ...302 Administrator Guide Document Version 2014 04 7 5 SSH Settings Debug Settings...
Page 303: ...Index Document Version 2014 04 Administrator Guide 303...