The data saved to the USB memory device
will be named "hdvclogall_XXXX.tar". The
"XXXX" portion of the file name varies
depending on the software version and date
of the export.
•
The contacts list (address.xml), profile
(profile.xml), configuration data
(config.xml), encryption data
(sec_config.xml), and multicast tree list
(alm_config_list.xml) that are included in
the file "hdvclogall_XXXX.tar" can be
imported into the unit. However, when using
a KX-VC1000 that has not been expanded
for 4 Point Built-in MCU support, profile
(profile.xml) cannot be imported.
•
For information about editing the exported
contacts list (address.xml) or profile
(profile.xml), contact your dealer.
4.
Check the result (successful/failed) and press
[ENTER]
.
•
The administrator menu screen is displayed.
5.
Remove the USB memory device.
Note
•
To prevent data leakage from the USB memory
device, make sure to erase all data from the
USB memory device before disposing of,
lending, or returning it.
Importing Data
The contacts list and other data exported from the unit
can be re-imported from a USB memory device.
Note
•
Encryption data exported from the unit includes
login IDs and passwords. Note that when
encryption data is imported, login IDs and
passwords may change and login can no longer
be performed.
•
When importing data that was exported from a
unit that had profile standby set to
"Permanent"
, import the profile and
configuration data together.
•
When importing data that was export from the
unit that registered the local site information
(Page 113), import encryption data and
configuration data.
•
A mass storage class (FAT16 or FAT32 format)
compatible USB memory device can be used
with this unit.
•
The following types of USB memory devices
cannot be used:
–
U3 smart drives (USB memory devices
compatible with the U3 platform)
–
USB memory devices with security features
–
USB memory devices formatted using
NTFS
–
USB memory devices with multiple LUNs
(Logical Unit Numbers)
–
USB memory devices formatted with
multiple partitions
•
USB memory devices are not guaranteed to
fully operate. For details, contact your dealer.
•
To re-connect a USB memory device, make
sure to fully remove the USB memory device
before connecting it again.
•
You can import a startup screen to change the
default startup screen.
1.
Prepare the USB memory device that contains the
data that will be imported.
•
The file names of the files that can be imported
are fixed as follows.
–
Contacts list: address.xml
–
Profile: profile.xml
–
Configuration data: config.xml
–
Encryption data: sec_config.xml
–
Startup screen: startup.png
–
Multicast tree list: alm_config_list.xml
•
Store the data to be imported in the root
directory of the USB memory device, or in a
folder stored in the root directory (folder names:
01–16).
•
For the startup screen, use the PNG file format
for an image that is 960
´
540 pixels or smaller.
Note
•
When using a KX-VC1000 that has not
been expanded for 4 Point Built-in MCU
support, profile (profile.xml) cannot be
imported.
2.
Connect the USB memory device to the USB jack
on the back of the unit (Page 23).
Note
•
Make sure that the USB memory device is
connected correctly.
Document Version 2018-01
User Manual
157
Contacts and Settings